R Normal Contacts - P/N Characteristics and Ins/Ext Tools R EN3155-016 and ABS1493 R Figure 019
20-48-24 Page 26
R Normal Contacts - Shrinking Characteristics R EN3155-016 and ABS1493 R Figure 020
20-48-24 Page 27
R Normal Contacts - Stripping Characteristics and Tools R EN3155-016 and ABS1493 R Figure 021
20-48-24 Page 28
R Normal Contacts - Crimping Tools R EN3155-016 and ABS1493 R Figure 022
20-48-24 Page 2920-48-24 Page 30
-Slide the sleeve near the contact rear. -Heat shrink the sleeve.
____NOTE : It is not necessary to shrink the sleeve on the standard element leg.
R ___________________________________________6. Connection Procedure for Contact EN3155-017
R A. Contact P/N and Characteristics (Ref. Fig. 023) ---------------------------------------------------------------------
R | | USE WITH | | CONTACT |----------------------------------------------| | | PLUG | RECEPTACLE | |--------------------|-----------------------|----------------------| | | Relay bases EN2593 | | | EN3155-017 | E0219-E0247-E0249 | ------| | | E0250-E0251-E0311 | | | | E0673-E0745-E0746 | | ---------------------------------------------------------------------
B. Temperature Minimum operating temperature is -65 deg.C (-85.00 deg.F). Maximum operating temperature is 125 deg.C (257.00 deg.F).
R C. Contact Insertion and Extraction Tools (Ref. Fig. 024)
R R R D. Wire Stripping (Ref. Fig. 024) - If necessary, install the heat shrinkable sleeve on the wire before stripping. Shrinking is done after crimping. - Use the applicable tool. - Strip the wire to the length "A".
R E. Crimping Procedure (Ref. Fig. 025) - Engage the stripped wire in the contact. - Make sure that you can see the wire through the contact hole. - Use the applicable tool. - Install the contact in the positioner. - Fully close the tool handles until the safety ratchet releases. - Remove the crimped contact. - If installed, retract the sleeve.
Normal Contacts - P/N Characteristics EN3155-017 R Figure 023
20-48-24 Page 31
Normal Contacts - Stripping and Ins/Ext Tools EN3155-017 R Figure 024
20-48-24 Page 32
Normal Contacts - Crimping Tools EN3155-017 R Figure 025
20-48-24 Page 33
R
R
R
R
R
__________________________________________________________________________
7. Connection Procedure for Contacts EN3155-044, EN3155-045 and EN3155-054 to EN3155-057
A. Contact P/N and Characteristics
(Ref. Fig. 026) ---------------------------------------------------------------------| | USE WITH | | CONTACT |----------------------------------------------| | | PLUG | RECEPTACLE | |--------------------|-----------------------|----------------------| | EN3155-044 | | | | EN3155-045 | | | | EN3155-054 | EN2997 | EN2997 | | EN3155-055 | | | | EN3155-056 | | | | EN3155-057 | | | ---------------------------------------------------------------------
B. Temperature
Minimum operating temperature is -65 deg.C (-85.00 deg.F).
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 ESPM Electrical Standard Practices Manual 4(37)