(5)
Fully close the tool handles until the safety ratchet releases.
(6)
Remove the crimped contact.
(7)
If sealing is necessary: Heat shrink the sleeve. If it is necessary to use several sleeves, wait until the first sleeve is fully cool before you shrink the other sleeves.
20-48-23 Page 48
___________________________________________10. Connection Procedure for Contacts NSA938192
A. Contact P/N and Characteristics
(Ref. Fig. 036) ---------------------------------------------------------------------| | USE WITH | | CONTACTS |------------------------------------------------| | | PLUG | RECEPTACLE | |------------------|-------------------------|----------------------| | NSA938192 | NSA938925 | NSA938925 | ---------------------------------------------------------------------
B. Contacts Insertion / Extraction Tools
(Ref. Fig. 037)
C. Wire Stripping
(1) Normal wire
(Ref. Fig. 037, 038)
-If sealing is necessary, install the heat-shrinkable sleeve on the wire before stripping. Shrinking is made after crimping.
-Select the applicable tool.
-Strip the wire to the length "A".
D. Crimping Procedure and Tools
(Ref. Fig. 039, 040)
(1)
If necessary, install the reducer on the conductor.
(2)
Install the pin/socket contact in the positioner.
(3)
Engage the stripped wire in the pin/socket.
(4)
Make sure that you can see the wire conductor through the pin/socket hole.
(5)
Fully close the tool handles until the safety ratchet releases.
(6)
Remove the crimped contact.
(7)
If sealing is necessary:
(a)
Heat shrink the sleeve if installed before stripping
(b)
If it is necessary to use several sleeves, wait until the first sleeve is fully cool before you shrink the other sleeves.
20-48-23 Page 49
Normal Contacts - P/N Characteristics
NSA938192
Figure 036
20-48-23 Page 50
R Normal Contacts - Insertion/Extraction and Stripping Tools NSA938192 Figure 037
20-48-23 Page 51
Normal Contacts - Sleeve Allocation and Shrinking Tool.
NSA938192
Figure 038
20-48-23 Page 52
Normal Contacts - Crimping Tools
NSA938192
Figure 039
20-48-23 Page 53
Normal Contacts - Crimping Tools
NSA938192
Figure 040
20-48-23 Page 5420-48-24 Page 1
_______________________________________________________________NORMAL CONTACTS FOR PREN CONNECTORS - DESCRIPTION AND OPERATION
_______1. General
This chapter gives the connection procedure for Normal Contacts used for
PREN type Connectors. These contacts have the codes that follow:
R - ABS1380 and ABS1381
- E0445, E0446, EN3155-004 and EN3155-005
- EN3155-003, EN3155-008, EN3155-014 and EN3155-015
R - EN3155-016 and ABS1493
- EN3155-017
- EN3155-044, EN3155-045 and EN3155-054 to EN3155-057
- EN3155-052 and EN3155-053.
R
R _____________________________________________________2. Connection Procedure for Contacts ABS1380 and ABS1381
R (Ref. Fig. 001)
R A. Contact P/N and Characteristics
R ---------------------------------------------------------------------
R | | USE WITH |
R | CONTACT |------------------------------------------------|
R | | PLUG | RECEPTACLE |
R |------------------|-------------------------|----------------------|
R | ABS1380 | ABS1340 | ABS1426 |
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 ESPM Electrical Standard Practices Manual 4(34)