20-53-21 Page 1
NSA935387 QE
R * Cables with coating, these cables have P/Ns: R E0262 or EN2267-004A DK-C, E0262 or EN2267-005A DK-U R
20-53-21 Page 220-53-21 Page 3
R _______________________2. Damage Check Procedure:
R R A. Single-Core Cables for Panels and Boxes, Low-Temperature 200 deg.C (392.00 deg.F)
R R (1) Cable layout (Ref. Fig. 001)
R R (2) Table for damage assessment (Ref. Fig. 001)
B. Single-Core or Multi-Core Cables, Unscreened, Low-Temperature 200 deg.C (392.00 deg.F)
(1) Cable layout (Ref. Fig. 002)
(2) Table for damage assessment (Ref. Fig. 002)
(3) When the repair type is selected, refer to:
(a) Para. 3 Repair Procedure for the general description and conditions of application.
(b) 20-53-29 GENERAL REPAIR PROCEDURE for more data.
C. Single-Core or Multi-Core Cables, Unscreened, High-Temperature 260 deg.C (500.00 deg.F)
R (1) Cables without coating , four insulation layers
R R (a) Cable layout (Ref. Fig. 003)
R R (b) Table for damage assessment (Ref. Fig. 003)
R (c) When the repair type is selected, refer to:
R R _1 Para. 3 Repair Procedure for the general description and conditions of application.
R _2 20-53-29 GENERAL REPAIR PROCEDURE for more data.
R Layout and Table for Damage Assessment BE and BF Figure 001
20-53-21 Page 4
R Layout and Table for Damage Assessment AK, CF, PD, PF, QD, QF, RD, and RF Figure 002
20-53-21 Page 5
R Layout and Table for Damage Assessment R DG R Figure 003
20-53-21 Page 620-53-21 Page 7
R (2) Cables without coating
R (a) Cable layout
R (Ref. Fig. 004)
R (b) Table for damage assessment
R (Ref. Fig. 004)
R (c) When the repair type is selected, refer to:
R _1 Para. 3 Repair Procedure for the general description and
R conditions of application.
R _2 20-53-29 GENERAL REPAIR PROCEDURE for more data.
R (3) Cables with coating
R
R (a) Cable layout
R
R (Ref. Fig. 005)
R
R (b) Table for damage assessment
R
R (Ref. Fig. 005)
R
R (c) When the repair type is selected, refer to:
R
R _1 Para. 3 Repair Procedure for the general description and
R conditions of application.
R
R _2 20-53-29 GENERAL REPAIR PROCEDURE for more data.
________________3. Repair Procedure
R
A. Procedure
R (Ref. Fig. 006, 007, 008, 009)
This paragraph gives the general description and conditions of
application for each repair scheme.
R ____NOTE : For detailed description and additional information, refer to
R 20-53-29 GENERAL REPAIR PROCEDURE.
R Layout and Table for Damage Assessment R DE, DK, DM, DR, PE, PG, PN, QE, QG, QL, RE, RH and RK R Figure 004
20-53-21 Page 8
R Layout and Table for Damage Assessment R DK-C, DK-U R Figure 005
20-53-21 Page 9
Repair of Standard Cables - Repair Procedure Table AK, CF, DE, DK, PD, PE, PF, PG, QD, QE, QF, QG, RD, RE, RF and RH R Figure 006
20-53-21 Page 10
Repair of Standard cables - Repair Procedure Table AK, CF, DE, DK, PD, PE, PF, PG, QD, QE, QF, QG, RD, RE, RF and RH. R Figure 007
20-53-21 Page 11
R Repair of Standard Cables - Repair Procedure Table R DG R Figure 008
20-53-21 Page 12
R Repair of Standard Cables - Repair Procedure Table R DG R Figure 009
20-53-21 Page 13
B. Allocation Table of Heat-Shrink Repair Sleeves
R (Ref. Fig. 010, 011, 012) The tables that follow give the different types of sleeves that you can use for repair, in relation to the type and gauge of the cable (Refer to Chapter 20-42-12 for SLEEVE SHRINKING PROCEDURE)