 4. Procedure
_________

 Subtask 56-31-13-420-050
 A. Installation of the Window (Ref. Fig. 401/TASK 56-31-13-991-001, 402/TASK 56-31-13-991-002)
 (1) Assembly of the Window
 (a) Install the seal (9) so that it attaches the inner pane (8) and the outer pane (10).
 NOTE : After the assembly, make sure that there is(are) no dust,____ particles or other contamination between the two panes.
 (2) Installation of the Window
 (a) Put the window (5) in position on the frame (6).
 (b) Make sure that the hole (11) in the inner pane of the window (5) is at the bottom.
 (c) Install the screws (1), the washers (2), the retainer (3) and the spacer (4) on the frame (6).
 NOTE : Make sure that the retainer (3) is on the correct____ position.
 NOTE : Use a spacer which compresses the seal 0.5 mm (0.0196 in.)____ around the edge when you TORQUE it to between 0.3 and 0.4 m.daN (26.54 and 35.39 lbf.in).
 (d) TORQUE the screws (1) to between 0.3 and 0.4 m.daN (26.54 and 35.39 lbf.in).
 Subtask 56-31-13-220-051
 B. Inspection (Ref. Fig. 403/TASK 56-31-13-991-003) 
R R R R R R  NOTE : The out-of-flush values specified in this procedure are for a new____ outer pane (acrylic) (thickness of new pane: 5.4 mm (0.2125 in.) to 5.6 mm (0.2204 in.)). If you install a reworked pane, the maximim out-of-flush values are equal to the specified values minus the thickness of acrylic removed by the rework (maximum rework is 0.7 mm (0.0275 in.)).

 1EFF : ALL 1 56-31-13Page 406 1 1 Nov 01/00 1 1 1CES 1


 Alignement of the Window
 Figure 403/TASK 56-31-13-991-003
 1EFF :  ALL  1  56-31-13 Page 407 
1  1  Feb 01/98
 1  1
 1CES  1

 

 (1) Make sure that the out-of-flush tolerances between the window and the frame are: 
R  (a) J1' 0.5 -1 +1 mm (0.0196 -0.0393 +0.0393 in.). 
R R  NOTE : For a maximum rework of 0.7 mm (0.0275 in.), the value is:____ - J1' -0.2 -1 +1 mm (-0.0078 -0.0393 +0.0393 in.). 
R  (b) J2' 0 -1 +1 mm (0.0000 -0.0393 +0.0393 in.). 
R R  NOTE : For a maximum rework of 0.7 mm (0.0275 in.), the value is:____ - J2' -0.7 -1 +1 mm (-0.0275 -0.0393 +0.0393 in.). 
R  (c) J3' 0.5 -1 +1 mm (0.0196 -0.0393 +0.0393 in.). 
R R  NOTE : For a maximum rework of 0.7 mm (0.0275 in.), the value is:____ - J3' -0.2 -1 +1 mm (-0.0078 -0.0393 +0.0393 in.). 
R  (d) J4' -1.2 -1 +1 mm (-0.0472 -0.0393 +0.0393 in.). 
R R  NOTE : For a maximum rework of 0.7 mm (0.0275 in.), the value is:____ - J4' -1.9 -1 +1 mm (-0.0748 -0.0393 +0.0393 in.).
 5. Close-up________
 Subtask 56-31-13-410-050
 A. Installation of the Lining Panels
 (1) Make sure that the work area is clean and clear of tool(s) and other items.
 (2) Install the lining panel 832DZ 842DZ (Ref. TASK 25-23-46-400-002).
 (3) Close the aft passenger/crew door 832 or 842 (Ref. TASK 52-10-00-410-001).
 Subtask 56-31-13-942-050
 B. Close Access
 (1) Remove the access platform(s).

 1EFF : ALL 1 56-31-13Page 408 1 1 Nov 01/00 1 1 1CES 1 WINDOW - EMERGENCY EXIT DOOR - REMOVAL/INSTALLATION


___________________________________________________
 TASK 56-31-15-000-001
 Removal of the window from the Emergency Exit Door - Doors 2/3
 1. Reason for the Job
__________________
 Self Explanatory
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific cotton gloves No specific lint-free cloth No specific access platform 3.0 m (9 ft. 10 in.)
 B. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
25-23-47-000-004 Removal of the Door Frame Linings of the LH FWD Emergency Exit Door, zone 231 25-23-47-000-009 Removal of the Door Frame Linings of the RH FWD Emergency Exit Door, zone 232 25-23-47-000-010 Removal of the Door Frame Linings of the LH/RH AFT Emergency Exit Doors, zones 251/252. 52-22-00-010-001 Opening of the Emergency Exit Doors from the
 Passenger Compartment 52-22-00-010-002 Opening of the Emergency Exit Doors from the Outside 56-31-15-991-001 Fig. 401
 1EFF : 301-399, 1 56-31-15Page 401 1 1 May 01/04 1 1 1CES 1