R R R R  (1) For the acrylic fixed window (LUCAS supplier, P/N NH...) put the fixed window panel in position to get: - the clearance J1 of 1.2 +1.3 -0.8 mm (0.0472 +0.0511 -0.0314 in.) - the clearance J2 of 0.7 mm (0.0275 in.) minimum. 
R R R  (2) For the glass fixed window (PPG supplier, P/N NP...) put the fixed window panel in position to get: - the clearance J1 of 1.2 +1.3 -0.8 mm (0.0472 +0.0511 -0.0314 in.) 
R R R  (3) For the glass fixed window (SPS supplier, P/N SPSA...) put the fixed window panel in position to get: - the clearance J1 of 1.2 +1.3 -0.8 mm (0.0472 +0.0511 -0.0314 in.) 
R  **ON A/C 001-049, 101-149, 151-199, 201-299, 301-399, 401-499,
 Subtask 56-11-12-420-063
 C. Torque of the Fixed Window Panel Fasteners (Ref. Fig. 405/TASK 56-11-12-991-054, 406/TASK 56-11-12-991-055, 407/TASK 56-11-12-991-056, 408/TASK 56-11-12-991-057)
 (1) TORQUE the screws (12) to between 1.6 and 1.8 m.daN (11.79 and 13.27 lbf.ft) in the attachment holes in this sequence shown in the figure.
 Subtask 56-11-12-220-056
 D. Check of the Clearances (Ref. Fig. 406/TASK 56-11-12-991-055, 407/TASK 56-11-12-991-056, 408/TASK 56-11-12-991-057)
 (1) For the acrylic fixed window (LUCAS supplier, P/N NH...) make sure that the out-of-flush clearance between the window and the frame is: - for A1: 0 +0.5 -0.5 mm (0.0000 +0.0196 -0.0196 in.).
 (2) For the glass fixed window (PPG supplier, P/N NP...) make sure that the out-of-flush clearance between the window and the frame is: - for A1: 0 +0.5 -0.5 mm (0.0000 +0.0196 -0.0196 in.). 

R 1EFF : 001-049, 101-149, 151-199, 201-299, 1 56-11-12Page 426 1301-399, 401-499, 1Aug 01/05 1 1 1CES 1


 (3) For the glass fixed window (SPS supplier, P/N SPSA...) make sure that the out-of-flush clearance between the window and the frame is:
 -
for A1: 0.6 +0.6 -0.6 mm (0.0236 +0.0236 -0.0236 in.)

 -
for A2: 0. +0.5 -0.5 mm (0.0000 +0.0196 -0.0196 in.)


 Subtask 56-11-12-914-061
 E. Sealant Application
 WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL
_______ MATERIALS ONLY WITH A GOOD SUPPLY OF AIR. OBEY THE MANUFACTURERS INSTRUCTIONS. PUT ON PROTECTIVE CLOTHING. DO NOT GET THEM IN YOUR MOUTH. DO NOT SMOKE. DO NOT BREATHE THE GAS. THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN IRRITANT. GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.
 (1) Apply SEALANTS (Material No. 09-016) or SEALANTS (Material No. 09-053) in the intersection area between the retainers and the structure to fill the remaining spaces.
 NOTE : For the sealant cure time, refer to the supplier technical
____
 data-sheet.

 (2)
 Remove the remaining sealant from the intersection area and make sure that the bead of sealant is continuous.

 (3)
 Clean the external surfaces of the structure with CLEANING AGENTS (Material No. 11-003) and MISCELLANEOUS (Material No. 19-003)


 Subtask 56-11-12-420-064
 F. Installation of the Lining Panels.
 (Ref. Fig. 404/TASK 56-11-12-991-053)

 (1)
 Put the lining panel (8) in position.

 (2)
 Tighten the fasteners (2).

 (3)
 Install the washers (7) and the screws (6). Tighten the screws (6).


R 1EFF : 001-049, 101-149, 151-199, 201-299, 1 56-11-12Page 427 1301-399, 401-499, 1Aug 01/05 1 1 1CES 1


 (4) Install the lateral lining panel
R (a) FOR 7DG1 Put the panel (5) in position, tighten the fasteners (4), install the screws (3) and tighten them.
R (b) FOR 7DG2 Put the panel 212KW in position and tighten the fasteners (1).
 Subtask 56-11-12-865-058
 G. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 1DG1, 4DG1, 5DG1, 1DG2, 4DG2, 5DG2, 5SQ1, 5SQ2.
 Subtask 56-11-12-710-052
 H. Test
 (1) Do an operational test of the anti-ice and defogging system of the fixed windows (Ref. TASK 30-42-00-710-001).
 5. Close-up
________
 Subtask 56-11-12-110-057

 A. Cleaning
 (1) Clean the fixed windows (Ref. TASK 56-10-00-110-002)
 Subtask 56-11-12-942-057

 B. Close Access
 (1)
 Remove the ground support and maintenance equipment, the special and standard tools and all other items.

 (2)
 Remove the access platform(s).

 (3)
 Make sure that the work area is clean and clear of tool(s) and other items.


R 1EFF : 001-049, 101-149, 151-199, 201-299, 1 56-11-12Page 428 1301-399, 401-499, 1Aug 01/05 1 1 1CES 1 WINDOW - FIXED (7DG1,7DG2) - INSPECTION/CHECK


_____________________________________________ R **ON A/C 051-099,
 