R 1EFF : 051-099, 1 56-11-12Page 604 1 1 May 01/05 1 1 1CES 1
R Glass Fixed Window - Permitted Damage
R Figure 602/TASK 56-11-12-991-028
R 1EFF : 051-099, 1 56-11-12 Page 605
1 1 May 01/05
1 1
1CES 1
R Glass Fixed Window - Permitted Damage
R Figure 603/TASK 56-11-12-991-029
R 1EFF : 051-099, 1 56-11-12 Page 606
1 1 May 01/05
1 1
1CES 1
R Glass Fixed Window - Permitted Damage
R Figure 604/TASK 56-11-12-991-030
R 1EFF : 051-099, 1 56-11-12 Page 607
1 1 May 01/05
1 1
1CES 1
R Glass Fixed Window - Permitted Damage
R Figure 605/TASK 56-11-12-991-031
R 1EFF : 051-099, 1 56-11-12 Page 608
1 1 May 01/05
1 1
1CES 1
R Glass Fixed Window - Permitted Damage
R Figure 606/TASK 56-11-12-991-033
R 1EFF : 051-099, 1 56-11-12 Page 609
1 1 May 01/05
1 1
1CES 1
R Glass Fixed Window - Permitted Damage
R Figure 607/TASK 56-11-12-991-032
R 1EFF : 051-099, 1 56-11-12 Page 610
1 1 May 01/05
1 1
1CES 1
R Glass Fixed Window - Burn Spot Inspection Procedure R Figure 608/TASK 56-11-12-991-034
R 1EFF : 051-099, 1 56-11-12Page 611 1 1 May 01/05 1 1 1CES 1
R Subtask 56-11-12-942-055
R B. Close Access
R (1) Remove the ground support and maintenance equipment, the special and
R standard tools and all other items.
R (2) Remove the access platform(s).
R 1EFF : 051-099, 1 56-11-12Page 612 1 1 May 01/05 1 1 1CES 1
R **ON A/C 001-049, 101-149, 151-199, 201-299, 301-399, 401-499,
TASK 56-11-12-200-001
Inspection of the Fixed Windows
WARNING : MAKE SURE THAT THE CIRCUIT BREAKERS RELATED TO THE WEATHER RADAR ARE
_______ OPENED, SAFETIED AND TAGGED.
1. Reason for the Job
__________________
This procedure is applicable :
-
for the acrylic windows (LUCAS/ACT, P/N NH...)
-
for the glass windows (PPG supplier, P/N NP...)
-
for the glass windows (SPS supplier, P/N SPS...)
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific circuit breaker(s) safety clip(s) No specific hand-held magnifying glass No specific light source No specific metal scale 150 mm (5.9 in.) long No specific access platform 4.5 m (14 ft. 9 in.)
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
56-10-00-110-002 Cleaning of the L/R Fixed Windows 56-10-00-200-004 Measurement of Scratch Depth with MITUTOYO Surface
Tester SJ201 56-11-12-991-036 Fig. 609 56-11-12-991-037 Fig. 610 56-11-12-991-038 Fig. 611 56-11-12-991-039 Fig. 612 56-11-12-991-040 Fig. 613 56-11-12-991-041 Fig. 614 56-11-12-991-042 Fig. 615
R 1EFF : 001-049, 101-149, 151-199, 201-299, 1 56-11-12Page 613 1301-399, 401-499, 1Aug 01/05 1 1 1CES 1 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
56-11-12-991-043 Fig. 616 56-11-12-991-044 Fig. 617 56-11-12-991-045 Fig. 618 56-11-12-991-046 Fig. 619 56-11-12-991-048 Fig. 620 56-11-12-991-047 Fig. 621 56-11-12-991-049 Fig. 622 56-11-12-991-051 Fig. 623 56-11-12-991-050 Fig. 624 56-11-12-991-052 Fig. 625
3. Job Set-up
__________
Subtask 56-11-12-941-056
A. Get Access
(1)
Put the access platform in position at the zone 210.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM WINDOWS 风挡 窗户(42)