R Fixed Windows-Inner Lining
R Figure 401/TASK 56-11-12-991-023
R 1EFF : 051-099, 1 56-11-12 Page 403
1 1 May 01/05
1 1
1CES 1
R Fixed Windows
R Figure 402/TASK 56-11-12-991-024
R 1EFF : 051-099, 1 56-11-12 Page 404
1 1 May 01/05
1 1
1CES 1
R (e) Disconnect the sensor (11) from the receptacle (14).
R (f) Install blanking caps on the disconnected electrical connector.
R (g) Remove the screws (12).
R (2) Remove the fixed window panel (13).
R (a) Remove the nuts (16) and the bolts (15).
R (b) Carefully remove the retainers (18) and (20) from the window pane
R (19).
R (c) Remove the seal (17) from the retainer (20) and discard it.
R (d) Remove the fixed window panel (13).
R 1EFF : 051-099, 1 56-11-12Page 405 1 1 May 01/05 1 1 1CES 1
R TASK 56-11-12-400-002-A
R Installation of the Fixed Windows
R WARNING : MAKE SURE THAT THE CIRCUIT BREAKERS RELATED TO THE WEATHER RADAR ARE
_______ R OPENED, SAFETIED AND TAGGED.
R 1. Reason for the Job
__________________
R This procedure is applicable to the glass windows (SPS supplier, P/N R SPS...).
R 2. Job Set-up Information
______________________
R A. Fixtures, Tools, Test and Support Equipment
R -------------------------------------------------------------------------------R REFERENCE QTY DESIGNATION R -------------------------------------------------------------------------------
R No specific roller R No specific Torque Wrench : range 0.00 to 1.20 m.daN R (0.00 to 9.00 lbf.ft) R No specific Torque Wrench : range 0.20 to 3.60 m.daN R (2.00 to 26.00 lbf.ft)
R B. Consumable Materials
R -------------------------------------------------------------------------------R REFERENCE DESIGNATION R -------------------------------------------------------------------------------
R Material No. 05-002 R R Material No. 08-018 R R R Material No. 08-052 R R Material No. 09-016 R R R Material No. 09-053 R R Material No. 11-002 R R
USA MIL-P-8116
PUTTY, ZINC CHROMATE GENERAL PURPOSE (Ref. 20-31-00)
USA MMM-A-121
SOLVENT-BASED SYNTHETIC RUBBER ADHESIVE
(Ref. 20-31-00)
USA MIL-T-23397 AND/OR L-T-80B
SELF ADHESIVEALUMINIUM TAPE (Ref. 20-31-00)
USA MIL-PRF-81733D TYPE II CLASS B
CORROSION INHIBITING FILLET CONSISTENCY
(Ref. 20-31-00)
FAST-CURING SEALANT FOR WINDSCREENS (Ref. 20-31-00)
USA MIL-PRF-680
DRY CLEANING SOLVENT (VARSOL/WHITE SPIRIT)
(Ref. 20-31-00)
R 1EFF : 051-099, 1 56-11-12Page 406 1 1 May 01/05 1 1 1CES 1 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
R Material No. 11-003 USA ASTM D 740
R METHYL-ETHYL-KETONE (Ref. 20-31-00)
R Material No. 11-016 USA BOEING BAC 5000 BAC 5504 BAC 5750
R CLEANING SOLVENT (Ref. 20-31-00)
R Material No. 19-003 USA AMS 3819
R LINT-FREE COTTON CLOTH (Ref. 20-31-00)
R C. Expendable Parts
R -------------------------------------------------------------------------------
R FIG.ITEM |DESIGNATION |IPC-CSN
R -------------------------------------------------------------------------------
R 17 seal 56-11-01 02A-060
R 17 seal 56-11-01 02A-070
R D. Referenced Information
R -------------------------------------------------------------------------------
R REFERENCE DESIGNATION
R -------------------------------------------------------------------------------
R 30-42-00-710-001 Operational Test of the Windshield Anti-Icing and
R Defogging
R 56-10-00-110-002 Cleaning of the L/R Fixed Windows
R 56-11-12-991-023 Fig. 401
R 56-11-12-991-024 Fig. 402
R 56-11-12-991-026 Fig. 403
R 3. Job Set-up__________
R Subtask 56-11-12-869-052
R A. Aircraft Maintenance Configuration
R (1) Make sure that the access platform is in position at zone 210.
R 1EFF : 051-099, 1 56-11-12Page 407 1 1 May 01/05 1 1 1CES 1
Subtask 56-11-12-865-054
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320飞机维护手册 AMM WINDOWS 风挡 窗户(35)