R **ON A/C 109-149, 401-499,
R Subtask 56-11-11-220-053-A
R F. Check of the Clearances
R (Ref. Fig. 407/TASK 56-11-11-991-003)
R (1) Do a check of the clearances at the points given in the figure and
R make sure that:
R (a) The peripheral clearance J1 between the retainers and the window
R panel and between the window panel and the frame is 0 mm (0.0000
R in.) to 2.0 mm (0.0787 in.).
R (b) The out-of-flush dimension J2 between the window panel and the
R retainers is:
R 1_ 0.7 -0.6 +0.6 mm (0.0275 -0.0236 +0.0236 in.) for all the
R windshields (not applicable to SPS windshields P/N STA320-1-7
R and STA320-2-7 and to PPG windshields P/N NP165311-5 and P/N
R 165311-6).
R 2_ 0.7 -0.1 +1.4 mm (0.0275 -0.0039 +0.0551 in.) for SPS
R windshields P/N STA320-1-7 and STA320-2-7 and PPG windshields
R P/N NP165311-5 and P/N 165311-6.
R 3_ 1.4 -0.3 +1.8 mm (0.0551 -0.0118 +0.0708 in.) for PILKINGTON
R windshields P/N 06282 to P/N 06283.
R (c) The out-of-flush dimension J3 between the window panel and the
R retainers and between the window panel and the frame is:
R 1_ 0.7 -0.4 +0.4 mm (0.0275 -0.0157 +0.0157 in.) for all the
R windshields (not applicable to SPS windshields P/N STA320-1-7
R and STA320-2-7 and to PPG windshields P/N NP165311-5 and P/N
R 165311-6).
R 2_ 0.7 -0.1 -1.6 mm (0.0275 -0.0039 -0.0629 in.) for SPS
R windshields P/N STA320-1-7 and STA320-2-7 and PPG windshields
R P/N NP165311-5 and P/N 165311-6.
R 3_ 1.4 -0.3 +1.6 mm (0.0551 -0.0118 +0.0629 in.) for PILKINGTON
R windshields P/N 06282 to P/N 06283.
1EFF : 109-149, 401-499, 1 56-11-11Page 446 1 1 Aug 01/05 1 1 1CES 1 1EFF : ALL 1 56-11-11Page 447 1 1 Aug 01/05 1 1 1CES 1 1EFF : ALL 1 56-11-11Page 448 1 1 Aug 01/05 1 1 1CES 1
R (d) The peripheral clearance J4 between the retainers and the frame
R and between the retainers is 1 -0.5 +1 mm (0.0393 -0.0196 +0.0393
R in.).
R (e) The peripheral clearance J5 between the window panel and the
R retainers is 7 -1.0 +1.0 mm (0.2755 -0.0393 +0.0393 in.).
R (f) The out-of-flush dimension J6 between the retainers and the frame
R is 0 -0.9 +0.4 mm (0.0000 -0.0354 +0.0157 in.).
R **ON A/C ALL
R Subtask 56-11-11-914-055
R G. Sealant Application
R WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL_______
R MATERIALS ONLY WITH A GOOD SUPPLY OF AIR.
R OBEY THE MANUFACTURERS INSTRUCTIONS.
R PUT ON PROTECTIVE CLOTHING.
R DO NOT GET THEM IN YOUR MOUTH.
R DO NOT SMOKE.
R DO NOT BREATHE THE GAS.
R THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN IRRITANT.
R GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.
R (1) Apply SEALANTS (Material No. 09-019) around the icing indicator base
R which touches the external surface of the retainer.