(2)
Clean the aft upper rail (56) and its support with the CLEANING AGENTS (Material No. 11-003) and MISCELLANEOUS (Material No. 19-003).
R 1EFF : 001-049, 101-149, 151-199, 201-299, 1 56-12-11Page 438 1301-399, 401-499, 1Aug 01/05 1 1 1CES 1
TASK 56-12-11-400-001
Installation of the Sliding Windows
WARNING : MAKE SURE THAT THE CIRCUIT BREAKERS RELATED TO THE WEATHER RADAR ARE
_______ OPENED, SAFETIED AND TAGGED.
1. Reason for the Job
__________________
This procedure is applicable for:
-
for the acrylic windows (LUCAS/ACT supplier, P/N NH...)
-
for the glass windows (PPG supplier, P/N NP...)
-
for the glass windows (SPS supplier, P/N SPS...)
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------
No specific dynamometer 25 daN (56.2022 lbf)
No specific Torque Wrench : range 0.00 to 1.20 m.daN
(0.00 to 9.00 lbf.ft)
B. Consumable Materials
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 04-004 USA MIL-PRF-23827 TYPE I SYNTH.ESTER BASED GREASE HIGH PRESSURE (Ref. 20-31-00)
Material No. 08-002A GENERAL PURPOSE DIMETHACRYLATE GREEN (Ref. 20-31-00)
Material No. 09-019 USA AMS 3267/3 LOW ADHESION CORROSION INHIBITING SEALANT (Ref. 20-31-00)
Material No. 19-010 USA AMS 5687 LOCKWIRE STAINLESS STEEL ANNEALED 0.8MM DIA (Ref. 20-31-00)
R 1EFF : 001-049, 101-149, 151-199, 201-299, 1 56-12-11Page 439 1301-399, 401-499, 1Aug 01/05 1 1 1CES 1
C. Expendable Parts
-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------
66 adjustment washer 56-12-11 03 -285 66 adjustment washer 56-12-11 03C-285 67 adjustment washer 56-12-11 03 -285 67 adjustment washer 56-12-11 03C-285 81 lockwasher 56-12-11 02A-185 82 lockwasher 56-12-11 03C-185 83 lockwasher 56-12-11 02A-185 84 lockwasher 56-12-11 03C-185
D. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
30-42-00-710-001 Operational Test of the Windshield Anti-Icing and
Defogging 33-12-12-400-002 Installation of the Map Table lights (41LE, 42LE) 33-12-18-400-001 Installation of the Map Table Light Rheostats (39LE,
40LE)
56-10-00-110-003 Cleaning of the L/R Sliding Windows
56-12-11-410-001 Closing of the Cockpit Sliding Windows
56-12-11-991-065 Fig. 407
56-12-11-991-066 Fig. 408
56-12-11-991-067 Fig. 409
56-12-11-991-068 Fig. 410
**ON A/C 001-002,
56-12-11-991-069 Fig. 411
R **ON A/C 003-049, 101-149, 151-199, 201-299, 301-399, 401-499,
56-12-11-991-069-A Fig. 411A
R **ON A/C 001-049, 101-149, 151-199, 201-299, 301-399, 401-499,
56-12-11-991-008 Fig. 412
R 1EFF : 001-049, 101-149, 151-199, 201-299, 1 56-12-11Page 440 1301-399, 401-499, 1Aug 01/05 1 1 1CES 1 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
**ON A/C 001-049, 101-101,
56-12-11-991-079 Fig. 413
R **ON A/C 001-049, 101-149, 151-199, 201-299, 301-399, 401-499,
3. Job Set-up
__________
Subtask 56-12-11-869-053
A. Aircraft Maintenance Configuration
(1) Make sure that the access platform is in position at zone 211.
Subtask 56-12-11-865-063