Thus, the green indicator light 9MJ (8MJ) goes off as soon as the duplex door actuators 2502MJ and 2503MJ (2505MJ and 2506MJ) retract. This retraction closes the cargo door.
1EFF : ALL 1 52-35-00Page 41 1 1 Aug 01/05 1 1 1CES 1
CARGO COMPARTMENT DOOR ELECTRICAL CONTROL SYSTEM - ADJUSTMENT/TEST
__________________________________________________________________
R **ON A/C 001-049, 101-105,
TASK 52-35-00-710-001
Operational Test of the Door Control System
1.
Reason for the Job
__________________
Refer to the MPD TASK: 523500-01
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific access platform 2.1 m (6 ft. 11 in.)
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump 52-30-00-860-002 Close the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump
3. Job Set-up
__________
Subtask 52-35-00-010-050
A. Get Access
(1)
Open the access door 134AR or 154AR to get access to the selector of the control panel.
(2)
Open the FWD and/or AFT cargo-compartment door(s) (referred to as cargo door(s)) (Ref. TASK 52-30-00-860-001).
(3)
Put the access platform in position to the cargo door.
1EFF : ALL 1 52-35-00Page 501 1 1 May 01/05 1 1 1CES 1
4. Procedure
_________ Subtask 52-35-00-710-050
A. Operational Test NOTE : If the test does not show the correct results, stop it immediately
____
and repair the applicable parts.
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. In the door sill area:
-push down the pedal of the door sill latch 2004VU-1 (2004VU-3).
2. On the control panel:
R - turn the selector to the OPEN R position.
3. On the control panel:
-release the selector.
4. In the door sill area:
-release the door sill latch 2004VU-1 (2004VU-3),
-push down the pedal of the door sill latch 2004 VU-2 (2004 VU-4).
5. On the control panel:
-turn the selector to the OPEN position.
6. On the control panel:
-release the selector.
7. In the door sill area: In the door sill area:
-
the microswitch 2507MJ opens theground cargo door control circuit.
-
the Yellow electric pump 3075GX does not operate.
On the control panel:
-
the selector turns to the NEUTRAL position.
In the door sill area:
-
the microswitch 2507MJ closes theground cargo door control circuit,
-
the microswitch 2507MJ opens theground cargo door control circuit.
-
the Yellow electric pump 3075GX doesnot operate.
On the control panel:
-
the selector turns to the NEUTRAL position.
In the door sill area:
R 1EFF : 001-049, 101-105, 1 52-35-00Page 502 1 1 May 01/05 1 1 1CES 1
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
- release the door sill latch - the microswitch 2507MJ closes the
2004VU-2 (2004VU-4), ground cargo door control circuit,
- move down the overridable - the microswitch 2508MJ (2509MJ) opens
Y-latch of the door sill latch the ground cargo door control
2004VU. circuit.
8. On the control panel:
- turn the selector to the OPEN - the Yellow electric pump 3075GX does
position. not operate.
9. On the control panel: On the control panel:
- release the selector. - the selector turns to the NEUTRAL
position.
10. In the door sill area: In the door sill area:
- release the overridable - the microswitch 2508MJ (2509MJ)
Y-latch. closes the ground cargo door control
circuit.
11. On the control panel:
- turn the selector to the CLOSE - the cargo door starts to close.
position.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn