 Thus, the green indicator light 9MJ (8MJ) goes off as soon as the duplex door actuators 2502MJ and 2503MJ (2505MJ and 2506MJ) retract. This retraction closes the cargo door.
 1EFF : ALL 1 52-35-00Page 41 1 1 Aug 01/05 1 1 1CES 1


 CARGO COMPARTMENT DOOR ELECTRICAL CONTROL SYSTEM - ADJUSTMENT/TEST
__________________________________________________________________
R **ON A/C 001-049, 101-105,
 TASK 52-35-00-710-001
 Operational Test of the Door Control System

 1.
 Reason for the Job

__________________
 Refer to the MPD TASK: 523500-01


 2.
 Job Set-up Information


______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific  access platform 2.1 m (6 ft. 11 in.)
 B. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
52-30-00-860-001  Open the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump 52-30-00-860-002 Close the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump
 3. Job Set-up
__________
 Subtask 52-35-00-010-050

 A. Get Access
 (1)
 Open the access door 134AR or 154AR to get access to the selector of the control panel.

 (2)
 Open the FWD and/or AFT cargo-compartment door(s) (referred to as cargo door(s)) (Ref. TASK 52-30-00-860-001).

 (3)
 Put the access platform in position to the cargo door.


 1EFF : ALL 1 52-35-00Page 501 1 1 May 01/05 1 1 1CES 1


 4. Procedure
_________ Subtask 52-35-00-710-050
 A. Operational Test NOTE : If the test does not show the correct results, stop it immediately
____
 and repair the applicable parts.

 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. In the door sill area:
-push down the pedal of the door sill latch 2004VU-1 (2004VU-3).
2. On the control panel:
R - turn the selector to the OPEN R position.
3. On the control panel:
-release the selector.
4. In the door sill area:
-release the door sill latch 2004VU-1 (2004VU-3),
-push down the pedal of the door sill latch 2004 VU-2 (2004 VU-4).
 5. On the control panel:
 -turn the selector to the OPEN position.
6. On the control panel:
-release the selector.
7. In the door sill area: In the door sill area:
-
the microswitch 2507MJ opens theground cargo door control circuit.

-
the Yellow electric pump 3075GX does not operate.

On the control panel:

-
the selector turns to the NEUTRAL position.

In the door sill area:

-
the microswitch 2507MJ closes theground cargo door control circuit,

-
the microswitch 2507MJ opens theground cargo door control circuit.

-
the Yellow electric pump 3075GX doesnot operate.

On the control panel:

-
the selector turns to the NEUTRAL position.


In the door sill area:
R 1EFF : 001-049, 101-105, 1 52-35-00Page 502 1 1 May 01/05 1 1 1CES 1


 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
- release the door sill latch  - the microswitch 2507MJ closes the
 2004VU-2 (2004VU-4),  ground cargo door control circuit,
 - move down the overridable  - the microswitch 2508MJ (2509MJ) opens
 Y-latch of the door sill latch  the ground cargo door control
 2004VU.  circuit.
 8. On the control panel:
 - turn the selector to the OPEN  - the Yellow electric pump 3075GX does
 position.  not operate.
 9. On the control panel:  On the control panel:
 - release the selector.  - the selector turns to the NEUTRAL
 position.
 10. In the door sill area:  In the door sill area:
 - release the overridable  - the microswitch 2508MJ (2509MJ)
 Y-latch.  closes the ground cargo door control
 circuit.
 11. On the control panel:
 - turn the selector to the CLOSE  - the cargo door starts to close.
 position.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM DOORS 舱门6(87)