(b)
Attach the second layer of high-speed tape diagonally to overlap the first layer.
(c)
Attach the third layer of high-speed tape diagonally but in the opposite direction to the second layer.
5. Close-up
________
R **ON A/C 001-049, 051-099, 101-105,
Subtask 52-42-00-865-055-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s): -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 32MG A01 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 45MG A02 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 39MG A03 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 34MG A04 2001VU VACUUM TOILET SYSTEM/VACUUM SYS 35MG A06 2001VU VACUUM TOILET SYSTEM/VACUUM GEN 33MG A08
1EFF : ALL 1 52-42-00Page 413 1 1 May 01/05 1 1 1CES 1R **ON A/C 106-149, 151-199, 201-299,
Subtask 52-42-00-865-055-B
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s): -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2001VU VACUUM TOILET SYSTEM/LAVATORY POWER A 32MG A01 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 45MG A02 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER D 39MG A03 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER E 34MG A04 2001VU VACUUM TOILET SYSTEM/VACUUM SYS 35MG A06 2001VU VACUUM TOILET SYSTEM/VACUUM GEN 33MG A08
R **ON A/C 001-049, 051-099, 101-105,
Subtask 52-42-00-860-051-A
B. Put the aircraft back to its initial configuration.
(1)
Set the CARGO COMPT light switch 8LU on the service panel to the OFF position.
(2)
Close the BULK cargo compartment door (Ref. TASK 52-30-00-860-008) and the access door 162DW.
(3)
Make sure that the aircraft electrical circuits are de-energized (Ref. TASK 24-41-00-862-002).
(4)
Remove the access platform(s).
(5)
Make an entry in the aircraft technical log that the AFT lavatory service door is removed and temporarily closed with high-speed tape.