R (4) Move the door handle to the CLOSED position and push it into its
recess.
________
5. Close-up
Subtask 52-41-00-860-057
A. Put the aircraft back to its initial configuration.
(1)
De-energize the ground service network
(Ref. TASK 24-42-00-862-001)
(2)
Remove the ground support and maintenance equipment, the special and standard tools and all other items.
1EFF : ALL 1 52-41-00Page 223 1 1 Aug 01/05 1 1 1CES 1 1EFF : ALL 1 52-41-00Page 601 1 1 May 01/05 1 1 1CES 1 1EFF : ALL 1 52-41-00Page 602 1 1 May 01/05 1 1 1CES 1
ACCESS DOORS - INSPECTION/CHECK_______________________________
TASK 52-41-00-210-001
R R Detailed Inspection of the Door Seals.
1. Reason for the Job__________________
Refer to the MPD TASK: 524100-01
2. Job Set-up Information______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific No specific circuit breaker(s) safety clip(s)access platform 2.00 m (6 ft. 7 in.)
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
R 52-41-00-010-002 52-41-00-410-002 Open the Avionics Compartment Doors for AccessClose the Avionics Compartment Doors after Access
3. Job Set-up__________
Subtask 52-41-00-010-050
A. Get Access
R (1) Put an access platform in position at zone 811, 812, 822 or 824.
R R (2) Open the applicable access door 811, 812, 822 or 824 (Ref. TASK 52-41-00-010-002).
Subtask 52-41-00-865-050
B. Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------121VU EIS/SDAC1 AND 2/DOOR/DET/AVNCS 46WV P02
4. Procedure_________
Subtask 52-41-00-220-050
A. Inspection
R R (1) Do a detailed inspection of the door seals.
(2) Make sure that there are no signs of chafing and breaks.
5. Close-up________
Subtask 52-41-00-865-051
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 46WV
Subtask 52-41-00-410-050
B. Close Access
R R (1) Close the applicable access door 811, 812, 822 or 824 (Ref. TASK 52-41-00-410-002).
(2) Make sure that the work area is clean and clear of tool(s) and other items.
(3) Remove the access platform(s).
DOOR - AVIONICS COMPARTMENT, FWD - REMOVAL/INSTALLATION
_______________________________________________________ TASK 52-41-11-000-001 Removal of the Avionics-Compartment Forward Door
1.
Reason for the Job
__________________
Self Explanatory