曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 -
load-compressor discharge temperature - chromel/alumel
 thermocouple,

 

 -ambient pressure transducer (P2),
 -
load-compressor delta pressure transducer (DELTA P),

 -
load-compressor discharge total pressure-transducer (PT),


 -inlet-guide vane actuator-position (LVDT),
 -starter voltage,
 -APU serial number encoder,
 -
load control valve (open position) indication,

 -
load control valve (close position) indication,

 


 -low oil level switch,
 -clogged oil filter switch(es).

R **ON A/C 001-003, 051-099, 401-499,
 B. Explanations to the Parameter List The parameter list is organized according to the connected ARINC 429 data buses. The connected systems (e.g. FAC, ECU, EEC, etc.) and the corresponding ATA chapter numbers are stated in the header on the left side of each page of the parameter lists. The columns are described as follows:
 ---------------------------------------------------------------Column | Description ---------------|-----------------------------------------------1st | EQ.SYS.LAB.SDI = Parameter number
 SYS.LAB.SDI  | | System number: According to the system which is | sending out the corresponding parameter: | 1 for system one | 2 for system two | 3 for system three | Label of the parameter, octal value | according to ARINC 429. | SDI states the Source/Destination Identifier | which is used by the system for the | corresponding parameter: | 00 means SDI 00 (0) | 01 means SDI 01 (1) | 10 means SDI 10 (2) | 11 means SDI 11 (3)
 ---------------|------------------------------------------------2nd | PARAMETER PARAMETER | Parameter name ---------------|------------------------------------------------3rd | RANGE
 RANGE  | | Three different types of ranges are shown in | this column: | The first one, indicated by a 'W' (WORDRANGE), | is related to the ARINC 429 data bus. This | shows the maximum value of the parameter that | can be transferred on the bus. This | depends on the number of data bits (see


 ---------------------------------------------------------------
Column | Description ---------------|-----------------------------------------------
|  column DATA BITS) and the resolution ('R') of
 |  the parameter (see column ACCURACY).
 |  The second one, with no specific indication,
 |  shows the normal operational range of the
 |  parameter.
 |  The third one is related to the ARINC 429
 |  Discrete Data Words. There are two states:
 |  'bit status 0' or 'bit status 1'. They
 |  indicate the true condition of the
 |  corresponding data word bit position.

 ---------------|------------------------------------------------
4th  |  ACCURACY
 ACCURACY  |
 |  Two different types of values are shown
 |  in this column:
 |  The first one, indicated by an 'R'
 |  (RESOLUTION) is related to the ARINC
 |  429 data bus. It also shows the
 |  resolution of the data word. The second
 |  one, with no specific indication, shows
 |  the total accuracy of the parameter.

 ---------------|-----------------------------------------5th | SIGN BIT
 SIGN BIT  |
 | This column shows whether a sign bit
 | is available and in which bit position
 | of the data word it is situated.

 ---------------|-----------------------------------------6th | DATA BITS
 DATA BITS  |
 | Describes the number of data bits not
 | including the sign bit. 'A' and a number
 | means the discrete bit position in the
 | ARINC 429 data word.
 | For BCD coded data words the number of
 | significant data digits is shown,
 | indicated by '(1)'.

 ---------------|----------------------------------------------7th | UPD/sec
 UPD/sec  | | This column shows how many times the | parameter will be transmitted by the source | system.
 ---------------|----------------------------------------------


 ---------------------------------------------------------------
Column | Description ---------------|-----------------------------------------------8th | CODE
 CODE  |
 | BNR = binary data word
 | BCD = binary coded decimal data word
 | ISO = data word coded in ISO 5 Code
 | DIS = discrete data word
 | HEX = hexadecimal coded
 | OCT = octal coded
 | HYB = mixed code;
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 机载辅助动力 AIRBORNE AUXILIARY POWER5(69)