R EFF : 001-049, 101-105, 107-107, 151-154, 49-73-00Page 50 201-207, Config-2 Aug 01/05
CES
-------------------------------------------------------------------------------
FCN | Fault Description | CFDS Message | Class ----+----------------------------------------+-------------------------+-------
| Sensor > 66C | | ----+----------------------------------------+-------------------------+-------044 | ECB internal Failure | ECB (59KD) | 3 ----+----------------------------------------+-------------------------+-------045 | N O T U S E D | | ----+----------------------------------------+-------------------------+-------046 | EGT2 Sensor shows out of range low | EGT TCPLE RAKE 2 | 3 ----+----------------------------------------+-------------------------+-------047 | EGT2 Sensor disagrees with EGT1 | EGT TCPLE RAKE 2 | 3
| Sensor > 66C | | ----+----------------------------------------+-------------------------+-------048 | N O T U S E D | | ----+----------------------------------------+-------------------------+-------049 | N O T U S E D | | ----+----------------------------------------+-------------------------+-------050 | ECB internal Failure | ECB (59KD) | 2 ----+----------------------------------------+-------------------------+-------051 | Fuel Temp. Snsr. shows out | FUEL CONTROL UNIT P19 | 2
| of Range low | | ----+----------------------------------------+-------------------------+-------052 | Fuel Temp. Snsr. shows out | FUEL CONTROL UNIT P19 | 2
| of Range high | | ----+----------------------------------------+-------------------------+-------053 | ECB internal Failure | ECB (59KD) | 2 ----+----------------------------------------+-------------------------+-------054 | Oil Temp. Snr. shows out of | OIL TEMP SENSOR P11 | 2
| Range low | | ----+----------------------------------------+-------------------------+-------055 | Oil Sump Temp. Snr. shows out of | OIL TEMP SENSOR P11 | 2
| Range high | | ----+----------------------------------------+-------------------------+-------056 | ECB internal Failure | ECB (59KD) | 3 ----+----------------------------------------+-------------------------+-------057 | Inlet Temp Sensor shows out | INLET TEMP SENSOR P6 | 3
| of range low | | ----+----------------------------------------+-------------------------+-------058 | Inlet Temp Sensor shows out of | INLET TEMP SENSOR P6 | 3
| range high | | ----+----------------------------------------+-------------------------+-------059 | N O T U S E D | | ----+----------------------------------------+-------------------------+-------060 | Inlet Flap shows Flap open and | AIR INTAKE FLAP ACTUATOR| 3
| Flap closed | | ----+----------------------------------------+-------------------------+-------
R EFF : 001-049, 101-105, 107-107, 151-154, 49-73-00Page 51 201-207, Config-2 Aug 01/05
CES
-------------------------------------------------------------------------------
FCN | Fault Description | CFDS Message | Class ----+----------------------------------------+-------------------------+-------061 | Inlet Flap shows Flap open switch | AIR INTAKE FLAP ACTUATOR| 3
| open | | ----+----------------------------------------+-------------------------+-------062 | Inlet Flap shows Flap open and Flap | AIR INTAKE FLAP ACTUATOR| 3
| closed | | ----+----------------------------------------+-------------------------+-------063 | Inlet Flap shows Flap closed switch | AIR INTAKE FLAP ACTUATOR| 3
| open | | ----+----------------------------------------+-------------------------+-------064 | Inlet Flap shows Flap close circuit | AIR INTAKE FLAP ACTUATOR| 2
| open | | ----+----------------------------------------+-------------------------+-------065 | Inlet Flap shows Flap close circuit | AIR INTAKE FLAP ACTUATOR| 2
| short | | ----+----------------------------------------+-------------------------+-------066 | Inlet Flap shows Flap open circuit | AIR INTAKE FLAP ACTUATOR| 2