FCN | Fault Description | CFDS Message | Class ----+----------------------------------------+-------------------------+-------180 | ECB internal Failure | ECB (59KD) | 1 ----+----------------------------------------+-------------------------+-------181 | ECB internal Failure | ECB (59KD) | 2 ----+----------------------------------------+-------------------------+-------182 | ECB internal Failure | ECB (59KD) | 2 ----+----------------------------------------+-------------------------+-------183 | Power Supply Interrupt | POWER SUPPLY INTERRUPT | 2 ----+----------------------------------------+-------------------------+-------184 | N O T U S E D | | ----+----------------------------------------+-------------------------+-------185 | ECB internal Failure | ECB (59KD) | 1 ----+----------------------------------------+-------------------------+-------186 | | |
to | N O T U S E D | | 200 | | | ----+----------------------------------------+-------------------------+-------201 | No LRU Fault detected (used as default | FUEL CONTROL UNIT | 1
| for OVERSPEED shutdown) | (8022KM) / ECB (59KD) | ----+----------------------------------------+-------------------------+-------202 | No LRU Fault detected (used as default | --| -
| for EMERGENCY shutdown) | | ----+----------------------------------------+-------------------------+-------203 | No LRU Fault detected (used as default | --| -
| for ECB 1A shutdown) | | ----+----------------------------------------+-------------------------+-------204 | No LRU Fault detected (used as default | FCU (8022KM) / APU FUEL | 1
| for UNDERSPEED shutdown) | SUPPLY / APU ROTATION | ----+----------------------------------------+-------------------------+-------205 | No LRU Fault detected (used as default | IGV ACTUATOR (8014KM) / | 1
| for OVERTEMP onspeed shutdown) | FCU(8022KM) / ECB (59KD)| ----+----------------------------------------+-------------------------+-------206 | No LRU Fault detected (used as default | FCU(8022KM)/IGV ACTUATOR| 1
| for OVERTEMP start shutdown) | (8014KM)/STRT MOTOR(8KA)| ----+----------------------------------------+-------------------------+-------207 | No LRU Fault detected (used as default | --| -
| for SENSOR FAILURE shutdown) | | ----+----------------------------------------+-------------------------+-------208 | No LRU Fault detected (used as default | LOP SW(8091KM)/OIL PUMP/| 1
| for LOW OIL PRESS shutdown) | GEARBOX PRESS VALVE | ----+----------------------------------------+-------------------------+-------209 | No LRU Fault detected (used as default | CHECK IGNITION SYSTEM OR| 1
| for NO FLAME shutdown) | FCU(8022KM) / ECB (59KD)| ----+----------------------------------------+-------------------------+-------210 | No LRU Fault detected (used as default | --| -
-------------------------------------------------------------------------------
FCN | Fault Description | CFDS Message | Class ----+----------------------------------------+-------------------------+-------
| for FLAP NOT OPEN shutdown) | | ----+----------------------------------------+-------------------------+-------211 | No LRU Fault detected (used as default | OIL COOLER / COOLING | 1
| for HIGH OIL TEMP shutdown) | FAN / GEN SCAV PUMP | ----+----------------------------------------+-------------------------+-------212 | No LRU Fault detected (used as default | IGV ACTUATOR(8014KM)/FCU| 1
| for NO ACCELERATION shutdown) | (8022KM)/STRT MOTOR(8KA)| ----+----------------------------------------+-------------------------+-------213 | No LRU Fault detected (used as default | GEN SCAVENG PMP(8085KM)/| 1
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 机载辅助动力 AIRBORNE AUXILIARY POWER5(166)