• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-26 14:43来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 ----------------------------+----------+---------------------------------------IGV ACTUATOR (8014KM) | 49-23-51 | IGV LVDT PRI/SEC SHOWS OPEN CIRCUIT
 ----------------------------+----------+---------------------------------------IGV ACTUATOR (8014KM)/ | 49-23-51 | IGV LVDT EXCITATION SHOWS FAILURE ECB (59KD) | |
 ----------------------------+----------+---------------------------------------
FUEL CONTROL UNIT (8022KM) | 49-32-11 | FUEL TEMP SENSOR SHOWS OUT OF RANGE | | FUEL RESOLVER PRI/SEC SHOWS OPEN | | CIRCUIT | | FUEL RESOLVER POSITION SHOWS INCORRECT | | POSITION
 ----------------------------+----------+---------------------------------------FUEL CONTROL UNIT (8022KM)/| 49-32-11 | FUEL RESOLVER EXCITATION SHOWS FAILURE ECB (59KD) | | FUEL RESOLVER PRI/SEC SHOWS OPEN
 ----------------------------+----------+---------------------------------------INLET PRESS XDCR(8048KM) | 49-51-21 | INLET PRESS SNSR SHOWS OUT OF RANGE | | INLET PRESS SNSR SHOWS < 8 PSIA ON GND ----------------------------+----------+---------------------------------------LOAD CONTROL VALVE (8050KM)| 49-51-51 | LCV SHOWS NOT OPEN | | LCV SHOWS OPEN/CLOSED SWITCH FAILURE
 ----------------------------+----------+---------------------------------------WRG: LOAD VALVE OPEN | 49-61-00 | LCV OPEN SIGNAL SHOWS CIRCUIT FAILURE OPEN | |
 ----------------------------+----------+---------------------------------------


 -------------------------------------------------------------------------------
Text for CFDS Indication | ATA | BITE Detection (Failed LRUs)
 ============================+==========+======================================= WRG: START IN PROGRESS | 49-61-00 | START IN PROGRESS SHOWS CIRCUIT FAIL. ----------------------------+----------+---------------------------------------
WRG: APU AVAILABLE | 49-61-00 | APU AVAIL SHOWS CIRCUIT FAILURE
 ----------------------------+----------+---------------------------------------WRG: APU FAULT RELAY | 49-61-00 | APU FAULT RELAY SHOWS CIRCUIT FAILURE ----------------------------+----------+---------------------------------------
ECB (59KD) | 49-61-34 | ECB INTERNAL FAILURE ----------------------------+----------+---------------------------------------LOW OIL LEVEL | 49-93-00 | OIL LEVEL SHOWS LOW ----------------------------+----------+---------------------------------------LOW OIL PRESS SW (8091KM) | 49-94-14 | LOP SWITCH SHOWS OPEN CIRCUIT
 ----------------------------+----------+---------------------------------------OIL SUMP TEMP SENSOR | 49-94-15 | OIL TEMP SNSR SHOWS OUT OF RANGE (8084KM) | |
 ----------------------------+----------+---------------------------------------APU OIL HEATER (8093KM) | 49-96-51 | OIL HEATER FAILURE ----------------------------+----------+---------------------------------------


 (3) CLASS 3 Faults
 Table 3
 -------------------------------------------------------------------------------Text for CFDS Indication | ATA | BITE Detection (Failed LRUs) ============================+==========+======================================= NO DEMAND DATA FROM ECS | 21-63-34 | ECS ZONE CONTROLLER | | ECS DEMAND FAILURE ----------------------------+----------+---------------------------------------NO PACK DATA FROM ECS | 21-63-34 | ECS ZONE CONTROLLER PACK DATA FAILURE | | ----------------------------+----------+---------------------------------------
NO DATA FROM CFDIU  | 31-32-34 | CFDIU AC ID FAILURE
 | | CFDIU AC CONFIG FAILURE
 | | CFDIU FLIGHT PHASE FAILURE
 | | CFDIU GMT FAILURE
 | | CFDIU DATE FAILURE
 | | CFDIU BITE COMMAND FAILURE

 ----------------------------+----------+---------------------------------------AIR INTAKE FLAP ACTUATOR | 49-16-51 | INLET FLAP SHOWS FLAP OPEN AND FLAP (4015KM) | | CLOSED
 | | INLET FLAP SHOWS FLAP CLOSED SWITCH | | OPEN | | INLET FLAP SHOWS FLAP OPEN SWITCH OPEN
 ----------------------------+----------+---------------------------------------INLET TEMP SENSOR | 49-23-14 | INLET TEMP SENSOR SHOWS OUT OF RANGE (8010KM) | | HIGH
 | | INLET TEMP SENSOR SHOWS OUT OF RANGE | | LOW
 ----------------------------+----------+---------------------------------------LOAD COMPRESSR DISCHARGE | 49-23-16 | LCDT SENSOR SHOWS OUT OF RANGE LOW TEMP SENSOR (8012KM) | |
 ----------------------------+----------+---------------------------------------CONTACTOR (5KA) | 49-42-55 | MAIN START CONTACTOR SHOWS CLOSED ----------------------------+----------+---------------------------------------CONTACTOR (10KA) | 49-42-55 | BACKUP START CONTACTOR SHOWS CLOSED
 ----------------------------+----------+---------------------------------------WRG: ACFT TYPE PIN PROG | 49-61-00 | A/C PIN CODING DISAGREES / ECB (59KD) | |
 ----------------------------+----------+---------------------------------------ECB (59KD) | 49-61-34 | ECB INTERNAL FAILURE ----------------------------+----------+---------------------------------------
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 机载辅助动力 AIRBORNE AUXILIARY POWER5(185)