R EFF : 001-049, 101-105, 107-107, 151-154, 49-73-00Page 48 201-207, Config-2 Aug 01/05
CES
-------------------------------------------------------------------------------
FCN | Fault Description | CFDS Message | Class ----+----------------------------------------+-------------------------+-----------+----------------------------------------+-------------------------+-------007 | Speed Sensor 1 shows open circuit | SPEED SENSOR P26 | 3 ----+----------------------------------------+-------------------------+-------008 | Speed Sensor 2 shows open circuit | SPEED SENSOR P26 | 3 ----+----------------------------------------+-------------------------+-------009 | Speed Sensor 1 shows amplitude Failure | SPEED SENSOR P26 | 3 ----+----------------------------------------+-------------------------+-------010 | Speed Sensor 2 shows amplitude Failure | SPEED SENSOR P26 | 3 ----+----------------------------------------+-------------------------+-------011 | ECB internal Failure | ECB (59KD) | 3 ----+----------------------------------------+-------------------------+-------012 | ECB internal Failure | ECB (59KD) | 3 ----+----------------------------------------+-------------------------+-------013 | ECB internal Failure | ECB (59KD) | 3 ----+----------------------------------------+-------------------------+-------014 | ECB internal Failure | ECB (59KD) | 3 ----+----------------------------------------+-------------------------+-------015 | ECB internal Failure | ECB (59KD) | 1 ----+----------------------------------------+-------------------------+-------016 | Delta Press. Sensor shows out of range | DIFFERENTIAL PRESS XDCR | 1
| drift | P24 | ----+----------------------------------------+-------------------------+-------017 | Delta Press. Sensor shows out of range | DIFFERENTIAL PRESS XDCR | 1
| drift | P24 | ----+----------------------------------------+-------------------------+-------018 | Delta Press. Sensor shows out of range | DIFFERENTIAL PRESS XDCR | 1
| low | P24 | ----+----------------------------------------+-------------------------+-------019 | Delta Press. Sensor shows out of range | DIFFERENTIAL PRESS XDCR | 1
| high | P24 | ----+----------------------------------------+-------------------------+-------020 | ECB internal Failure | ECB (59KD) | 2 ----+----------------------------------------+-------------------------+-------021 | Inlet Press. Sensor shows out of range | INLET PRESS XDCR P22 | 2 ----+----------------------------------------+-------------------------+-------022 | Inlet Press. Sensor shows < 8 psia | INLET PRESS XDCR P22 | 2
| on ground | | ----+----------------------------------------+-------------------------+-------023 | Inlet Press. Sensor shows out of range | INLET PRESS XDCR P22 | 2
| low | | ----+----------------------------------------+-------------------------+-------024 | Inlet Press. Sensor shows out of range | INLET PRESS XDCR P22 | 2
| high | | ----+----------------------------------------+-------------------------+-------
R EFF : 001-049, 101-105, 107-107, 151-154, 49-73-00Page 49 201-207, Config-2 Aug 01/05
CES
-------------------------------------------------------------------------------
FCN | Fault Description | CFDS Message | Class ----+----------------------------------------+-------------------------+-------025 | ECB internal Failure | ECB (59KD) | 1 ----+----------------------------------------+-------------------------+-------026 | Total Pressure Sensr. shows out of | TOTAL PRESS XDCR P23 | 1
| range | | ----+----------------------------------------+-------------------------+-------027 | Total Pressure and Inlet Pressure | TOTAL PRESS XDCR P23 | 1
| disagree | | ----+----------------------------------------+-------------------------+-------028 | Total Pressure Sensr. shows out of | TOTAL PRESS XDCR P23 | 1
| range low | | ----+----------------------------------------+-------------------------+-------029 | Total Pressure Sensr. shows out of | TOTAL PRESS XDCR P23 | 1
| range high | | ----+----------------------------------------+-------------------------+-------030 | Press XDCR wiring shows open circuit | CHECK PRESS XDCR WIRING | 1 ----+----------------------------------------+-------------------------+-------031 | Press XDCR wiring open or ECB internal | CHECK PRESS XDCR WIRING | 1
| failure | / ECB (59KD) | ----+----------------------------------------+-------------------------+-------032 | ECB internal Failure | ECB (59KD) | 1 ----+----------------------------------------+-------------------------+-------033 | N O T U S E D | | ----+----------------------------------------+-------------------------+-------034 | N O T U S E D | | ----+----------------------------------------+-------------------------+-------035 | Both EGT Sensors failed | EGT TCPLE RAKES 1 + 2 | 1 ----+----------------------------------------+-------------------------+-------036 | EGT1 Sensor Failure and ECB Internal | EGT TCPLE RAKE 1 | 1
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 机载辅助动力 AIRBORNE AUXILIARY POWER5(177)