----------------------------+----------+---------------------------------------PRESS XDCRS (8044KM) / | 49-51-17 | TOTAL PRESSURE AND INLET PRESSURE (8048KM) | | DISAGREE
----------------------------+----------+---------------------------------------LOAD CONTROL VALVE | 49-51-51 | LOAD VALVE SOLENOID SHOWS CIRCUIT (8050KM) | | FAILURE
-------------------------------------------------------------------------------
Text for CFDS Indication | ATA | BITE Detection (Failed LRUs) ============================+==========+======================================= ----------------------------+----------+---------------------------------------
SURGE CONTROL VALVE | 49-51-52 | SCV TORQUE MOTOR SHOWS OPEN CIRCUIT
(8058KM) | | SCV TORQUE MOTOR SHOWS SHORT CIRCUIT | | SCV LVDT PRIMARY SHOWS OPEN CIRCUIT | | SCV POSITION DISAGREES WITH COMMAND
----------------------------+----------+---------------------------------------SURGE CONTROL VALVE | 49-51-52 | SCV LVDT EXCITATION CIRCUIT FAILURE (8058KM) / ECB (59KD) | |
----------------------------+----------+---------------------------------------SCV (8058KM) / PRESS | 49-51-52 | BLEED SHUTOFF DUE TO REVERSE FLOW XDCRS (8043KM)/(8044KM) | | CONDITION
----------------------------+----------+---------------------------------------ECB (59KD) | 49-61-34 | ECB INTERNAL FAILURE ----------------------------+----------+---------------------------------------SPEED SENSOR (8060KM) | 49-71-13 | SPEED SENSOR SHOWS AMPLITUDE FAILURE
----------------------------+----------+---------------------------------------SPEED SENSOR (8060KM) | 49-71-13 | SPEED SENSOR 1 + 2 FAILURE AND AND ECB (59KD) | | ECB INTERNAL FAILURE
----------------------------+----------+---------------------------------------EGT TCPLE RAKES(8057KM1) | 49-72-15 | BOTH EGT SENSORS FAILED AND (8057KM2) | |
----------------------------+----------+---------------------------------------EGT TCPLE RAKE (8057KM2) | 49-72-15 | EGT1 SENSOR FAILURE AND ECB INTERNAL AND ECB (59KD) | | FAILURE
----------------------------+----------+---------------------------------------EGT TCPLE RAKE (8057KM2) | 49-72-15 | EGT2 SENSOR FAILURE AND ECB INTERNAL AND ECB (59KD) | | FAILURE
----------------------------+----------+---------------------------------------GEN SCAV + LUBE FILTERS | 49-91-41 | OIL FILTER SHOWS CLOGGED (8069KM) / (8076KM) | |
----------------------------+----------+---------------------------------------OIL COOLER (8079KM) / | 49-91-44 | NO LRU FAULT DETECTED COOLING FAN (8053KM) | |
----------------------------+----------+---------------------------------------DEOIL SOLENOID (8083KM) | 49-91-49 | DEOIL SOLENOID SHOWS CIRCUIT FAILURE | | DEOIL SOLENOID SHOWS OPEN CIRCUIT
----------------------------+----------+---------------------------------------LOP SW(8091KM)/OIL PUMP | 49-94-14 | NO LRU FAULT DETECTED (8080KM)/DEOIL (8083KM) | |
----------------------------+----------+--------------------------------------- (2) CLASS 2 Faults
Table 2
-------------------------------------------------------------------------------Text for CFDS Indication | ATA | BITE Detection (Failed LRUs) ============================+==========+======================================= POWER SUPPLY INTERRUPT | 24-00-00 | POWER SUPPLY INTERRUPT ----------------------------+----------+---------------------------------------FIRE EMERG STOP RLY 6WF | 26-22-00 | LOW FUEL PRESSURE RELAY SHOWS | | OPEN/SHORT CIRCUIT ----------------------------+----------+---------------------------------------LOW FUEL PRESSURE | 28-20-00 | FUEL PRESSURE SHOWS LOW DURING APU | | RUN
----------------------------+----------+---------------------------------------AIR INTAKE FLAP ACTUATOR | 49-16-51 | INLET FLAP SHOWS FLAP CLOSE CIRCUIT (4015KM) | | OPEN/SHORT
| | INLET FLAP SHOWS FLAP OPEN CIRCUIT | | OPEN/SHORT | | INLET FLAP SHOWS FLAP CLOSE HIGH | | CURRENT | | INLET FALP SHOWS FLAP FAILED TO FULLY | | CLOSE
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 机载辅助动力 AIRBORNE AUXILIARY POWER5(184)