(4)
Examine the bleed load control valve connections for leaks (Ref. TASK 49-00-00-790-006). There must be no air leakage. The position indicator on the valve must indicate closed.
(5)
Shut-down the APU (Ref. TASK 49-00-00-860-009).
R EFF : 001-049, 101-105, 107-107, 151-199, 49-51-51Page 409 201-210, Config-2 Aug 01/05
CES 5. Close-up
________ Subtask 49-51-51-410-054
A. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Set the LIGHT control SW 11LJ to the OFF position.
(3)
Close the APU access doors 315AL, 316AR (Ref. TASK 52-41-00-410-001).
(4)
Remove the access platform(s). Subtask 49-51-51-860-055
B.
Aircraft Maintenance Configuration
(1)
Pressurize the reservoirs of the hydraulic systems.
(Ref. TASK 29-14-00-614-002).
(2)
De-energize the ground service network
(Ref. TASK 24-42-00-862-001).
(3)
Remove the warning notice(s).
R EFF : 001-049, 101-105, 107-107, 151-199, 49-51-51Page 410 201-210, Config-2 Aug 01/05
CES VALVE - SURGE CONTROL ((GTCP 36-300)) - SERVICING
_________________________________________________ R **ON A/C 001-003, 051-099, 401-499,
TASK 49-51-52-600-001 Clean Surge Valve Filter (GTCP 36-300) WARNING : DO NOT TOUCH THE APU UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS
_______
WHEN YOU DO THE MAINTENANCE TASK(S).
1.
Reason for the Job
__________________
Refer to the MPD TASK: 495100-01
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific blanking plugs
No specific circuit breaker(s) safety clip(s)
No specific access platform 3.5 m (11 ft. 6 in.)
No specific Torque Wrench : range 0.00 to 1.20 m.daN
(0.00 to 9.00 lbf.ft)
B. Consumable Materials
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
No specific lockwire-corrosion resistant steel 0.8 mm (0.032 in) dia
C. Expendable Parts -------------------------------------------------------------------------------
FIG.ITEM --------- |DESIGNATION ---------------------------------------- |IPC-CSN------------------------------
3 packing 49-51-52 01 -040
3 packing 49-51-52 01 -040A
7 packing 49-51-52 01 -060
7 packing 49-51-52 01A-060
7 packing 49-51-52 01A-060A
D. Referenced Information
------------------REFERENCE -------------------------------DESIGNATION ------------------------------
-------------------------------------------------------------------------------
24-42-00-861-001 Energize the Ground Service Network from the External Power 24-42-00-862-001 De-energize the Ground Service Network Supplied from the External Power 29-00-00-864-001 Put the Related Hydraulic System in the Depressurized
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 机载辅助动力 AIRBORNE AUXILIARY POWER5(32)