LAMPS SMOKE DETECTORS ú ú 04 Page 203 ú Oct 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
TASK 26-14-01-402-007
3. Install Lamp (Fig. 201)____________
A. References
(1)
AIPC 26-14-01 Fig. 1
(2)
WDM 26-16-21 thru WDM 26-16-29
B.
Access
(1)
Location Zone 231 Passenger Cabin First To Second Door, LH 241 Passenger Cabin Second to Third Door, LH 251 Passenger Cabin Third to Fourth Door, LH 261 Passenger Cabin Fourth Door to STA 2040, LH 271 Passenger Cabin STA 2040 To STA 2360, LH
C.
Procedure
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH REPLACEABLE ú
26-14-01
LAMPS SMOKE DETECTORS ú ú 04 Page 204 ú Oct 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
S 422-008
CAUTION: REPLACE THE LAMP WITH CM376AS10, GI376AS10, CM376AS15, OR
_______ GI376AS15 ONLY. IF YOU INSTALL AN INCORRECT LAMP, THE SMOKE DETECTORS WILL FAIL TO DETECT SMOKE FROM A CARGO COMPARTMENT FIRE.
(1) Install the lamp in the lamp and lens holder. Refer to this table.
~................................................................ | CONNECTOR | DETECTOR | LOCATION | .................................................................. | DM5171 | M5171 | DET A - MN DK CARGO SMOKE - ZONE 1 | | DM5172 | M5172 | DET B - MN DK CARGO SMOKE - ZONE 1 | | DM5173 | M5173 | DET A - MN DK CARGO SMOKE - ZONE 2 | | DM5174 | M5174 | DET B - MN DK CARGO SMOKE - ZONE 2 | | DM5175 | M5175 | DET A - MN DK CARGO SMOKE - ZONE 3 | | DM5176 | M5176 | DET B - MN DK CARGO SMOKE - ZONE 3 | | DM5177 | M5177 | DET A - MN DK CARGO SMOKE - ZONE 4 | | DM5178 | M5178 | DET B - MN DK CARGO SMOKE - ZONE 4 | | DM5179 | M5179 | DET A - MN DK CARGO SMOKE - ZONE 5 | | DM5180 | M5180 | DET B - MN DK CARGO SMOKE - ZONE 5 | | DM5181 | M5181 | DET A - MN DK CARGO SMOKE - ZONE 6 | | DM5182 | M5182 | DET B - MN DK CARGO SMOKE - ZONE 6 | | DM5183 | M5183 | DET A - MN DK CARGO SMOKE - ZONE 7 | | DM5184 | M5184 | DET B - MN DK CARGO SMOKE - ZONE 7 | | DM5185 | M5185 | DET A - MN DK CARGO SMOKE - ZONE 8 | | DM5186 | M5186 | DET B - MN DK CARGO SMOKE - ZONE 8 | | DM5187 | M5187 | DET A - MN DK CARGO SMOKE - ZONE 9 | | DM5188 | M5188 | DET B - MN DK CARGO SMOKE - ZONE 9 | | DM5189 | M5189 | DET A - MN DK CARGO SMOKE - ZONE 10| | DM5190 | M5190 | DET B - MN DK CARGO SMOKE - ZONE 10| | DM5191 | M5191 | DET A - MN DK CARGO SMOKE - ZONE 11| | DM5192 | M5192 | DET B - MN DK CARGO SMOKE - ZONE 11| | DM5193 | M5193 | DET A - MN DK CARGO SMOKE - ZONE 12| | DM5194 | M5194 | DET B - MN DK CARGO SMOKE - ZONE 12| | DM5195 | M5195 | DET A - MN DK CARGO SMOKE - ZONE 13| | DM5196 | M5196 | DET B - MN DK CARGO SMOKE - ZONE 13| | DM5197 | M5197 | DET A - MN DK CARGO SMOKE - ZONE 14| | DM5198 | M5198 | DET B - MN DK CARGO SMOKE - ZONE 14| | DM5199 | M5199 | DET A - MN DK CARGO SMOKE - ZONE 15| | DM5200 | M5200 | DET B - MN DK CARGO SMOKE - ZONE 15| | DM5201 | M5201 | DET A - MN DK CARGO SMOKE - ZONE 16| | DM5202 | M5202 | DET B - MN DK CARGO SMOKE - ZONE 16| 2............….............….....................................1
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH REPLACEABLE ú
26-14-01
LAMPS SMOKE DETECTORS ú ú 04 Page 205 ú Oct 10/95
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 747-400 MAINTENANCE MANUAL
(2) S 432-009Install the gasket and cover on the detector and locate screws. Tighten screws to seal detector.
NOTE:____ The detector cover must be air tight.
(3) S 862-010Close the circuit breakers, and remove DO-NOT-CLOSE identifiers: (a) P7 Overhead Circuit Breaker Panel 1) 7H16 CARGO SMOKE - MAIN DECK ZN 1-8 A 2) 7H17 CARGO SMOKE - MAIN DECK ZN 1-8 B 3) 7H18 CARGO SMOKE - MAIN DECK ZN 9-16 A 4) 7H19 CARGO SMOKE - MAIN DECK ZN 9-16 B