Subtask 53-11-00-110-099
B. Cleaning of the Structure
WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL_______ MATERIALS ONLY WITH A GOOD SUPPLY OF AIR. OBEY THE MANUFACTURERS INSTRUCTIONS. PUT ON PROTECTIVE CLOTHING. DO NOT GET THEM IN YOUR MOUTH. DO NOT SMOKE. DO NOT BREATHE THE GAS. THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN IRRITANT. GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.
R R (1) Clean the inspection area with CLEANING AGENTS (Material No. 11-004) and a lint-free cotton cloth MISCELLANEOUS (Material No. 19-003), if necessary.
4. Procedure_________
Subtask 53-11-00-220-065
R A. Inspection (Ref. Fig. 654/TASK 53-11-00-991-063)
R R R (1) Do a detailed inspection of the cabin floor structure below and 0.5 M (19.685 in.) around the galleys and the lavatories. The inspection is applicable between FR21 and FR24.
(2) Make sure that there is no:
(a) Corrosion damage: - If you find corrosion damage, refer to the Structural Repair Manual (Ref. SRM 512200 P.Block 001) for types of corrosion, inspection, removal and corrosion protection.
(b) Other damage (cracks, scratches, stress, marks, dents, bumps,...): - If you find other damage, refer to the Structural Repair Manual (Ref. SRM 511100 P.Block 001) for damage classification and corrective action.
R Floor Structure, FR21 to FR24 Figure 654/TASK 53-11-00-991-063
EFF : ALL 53-11-00 Page B615 Aug 01/03
CES
Subtask 53-11-00-916-059
R B. Application of the Temporary Protection
CAUTION : DO NOT APPLY TEMPORARY PROTECTION ON THE OXYGEN SYSTEMS._______ MAKE SURE THAT THE TEMPORARY PROTECTION DOES NOT GET: -ON COMPOSITE PARTS, CONTROL CABLES, PULLEYS,TEFLON BEARINGS. -ON LUBRICATED SURFACES. -IN DRAIN VALVES OR OTHER ORIFICES. TEMPORARY PROTECTION ON OR IN THESE PARTS CAN CAUSE DAMAGE.
(1) Apply masking paper or masking tape BONDING AND ADHESIVE COMPOUNDS (Material No. 08-074) on the equipment and fitting adjacent to the area.
R R (2) Apply a layer of STORAGE PRESERVATION (Material No. 15-005) or STORAGE PRESERVATION (Material No. 15-006) to the inspection area.
(3) Apply a layer of STORAGE PRESERVATION (Material No. 15-008) or STORAGE PRESERVATION (Material No. 15-007) to the inspection area.
(4) Remove the masking tape or the masking paper.
5. Close-up________
Subtask 53-11-00-410-085
A. Close Access
R (1) Install the cabin floor panels from FR21 to FR24 (Ref. TASK 53-12-12-400-001).
R R (2) Install the galleys, if removed (Ref. TASK 25-31-41-400-002) (Ref. TASK 25-32-41-400-001) (Ref. TASK 25-31-41-000-001).
R R (3) Install the lavatories, if removed (Ref. TASK 25-41-42-400-001) (Ref. TASK 25-41-41-400-001) (Ref. TASK 25-42-41-400-001).
R R (4) Make sure that the work area is clean and clear of tool(s) and other items.
R R (5) Close the forward passenger/crew door 831 (841) (Ref. TASK 52-10-00-410-001).
R (6) Remove the access platform(s).
CES
TASK 53-11-00-210-034
Clean Door Girt Bar Fitting Stop Levers
1.
Reason for the Job
__________________
Refer to the MPD TASK: 256241-05
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------
No specific vacuum cleaner
No specific access platform 3.50 m (11 ft. 6 in.)
B. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
52-10-00-010-001 Opening of the Passenger/Crew Door
52-10-00-410-001 Closing of the Passenger/Crew Door
52-11-31-000-003 Removal of the Girt Bar Fittings
52-11-31-400-003 Installation of the Girt Bar Fittings
52-13-31-000-003 Removal of the Girt Bar Fittings
52-13-31-400-003 Installation of the Girt Bar Fittings
R 53-11-00-991-037 Fig. 655