R R  Forward Emergency Exit Cutouts - Internal Structure Figure 601/TASK 53-21-00-991-020- 12 (SHEET 1)  
R  EFF :  301-399,  53-21-00 Page 604 May 01/04 
 CES 
R R  Forward Emergency Exit Cutouts - Internal Structure Figure 601/TASK 53-21-00-991-020- 22 (SHEET 2)  
R  EFF :  301-399,  53-21-00 Page 605 May 01/04 
 CES 
R (2) Make sure that there is no:
R  (a) Corrosion damage:  
R  - If you find corrosion damage, refer to the Structural Repair  
R  Manual (Ref. SRM 512200 P.Block 001) for types of corrosion,  
R  inspection, removal and corrosion protection.  
R  (b) Other damage (cracks, scratches, stress, marks, dents,  
R  bumps,...):  
R  - If you find other damage, refer to the Structural Repair Manual  
R  (Ref. SRM 511100 P.Block 001) for damage classification and  
R  corrective action.  
R  Subtask 53-21-00-916-050  
R  B. Application of the Temporary Protection  
R  (Ref. Fig. 601/TASK 53-21-00-991-020)  
R  CAUTION : DO NOT APPLY TEMPORARY PROTECTION ON THE OXYGEN SYSTEMS._______  
R  MAKE SURE THAT THE TEMPORARY PROTECTION DOES NOT GET:  
R  -ON COMPOSITE PARTS, CONTROL CABLES, PULLEYS,TEFLON BEARINGS.  
R  -ON LUBRICATED SURFACES.  
R  -IN DRAIN VALVES OR OTHER ORIFICES.  
R  TEMPORARY PROTECTION ON OR IN THESE PARTS CAN CAUSE DAMAGE.  
R  (1) Put masking paper or masking tape BONDING AND ADHESIVE COMPOUNDS  
R  (Material No. 08-074) on the equipment and fittings adjacent to the  
R  area.  
R  (2) Apply a layer of STORAGE PRESERVATION (Material No. 15-005) or  
R  STORAGE PRESERVATION (Material No. 15-006) on the inspection area.  
R  (3) Remove the masking paper or masking tape.  
R  5. Close-up________  
R  Subtask 53-21-00-410-058  
R  A. Close Access  
R  (1) Make sure that the work area is clean and clear of tool(s) and other  
R  items.  
R  (2) Install the insulation blankets (Ref. TASK 25-80-00-400-001).  
R  (3) Install the overhead stowage compartments, if removed. 
CES
R  (4) Install the ceiling panels (Ref. TASK 25-23-41-400-001).  
R  (5) Install the cove light panels 231CX, 231FX, 231RX, 232CX, 232FX,  
R  232RX (Ref. TASK 25-23-48-400-001).  
R  (6) Install the sidewall panels 231AX, 232AX, 231PX, 232PX, 231BX, 232BX,  
R  231QX, 232QX (Ref. TASK 25-23-43-400-001).  
R  (7) Install the door frame linings (Ref. TASK 25-23-47-400-004)  
R  (Ref. TASK 25-23-47-400-009).  
R  (8) Close the forward emergency exit door 833 (843) (Ref. TASK 52-22-00- 
R  410-001).  
R  (9) Remove the access platform(s). 
R TASK 53-21-00-200-019
R Detailed Inspection of Door Stop Fittings on FR 35.1 and FR 35.2A, LH/RH R 1. Reason for the Job
__________________ R Refer to the MPD TASK: 532114-01 R 2. Job Set-up Information