R R Forward Emergency Exit Cutouts - Internal Structure Figure 601/TASK 53-21-00-991-020- 12 (SHEET 1)
R EFF : 301-399, 53-21-00 Page 604 May 01/04
CES
R R Forward Emergency Exit Cutouts - Internal Structure Figure 601/TASK 53-21-00-991-020- 22 (SHEET 2)
R EFF : 301-399, 53-21-00 Page 605 May 01/04
CES
R (2) Make sure that there is no:
R (a) Corrosion damage:
R - If you find corrosion damage, refer to the Structural Repair
R Manual (Ref. SRM 512200 P.Block 001) for types of corrosion,
R inspection, removal and corrosion protection.
R (b) Other damage (cracks, scratches, stress, marks, dents,
R bumps,...):
R - If you find other damage, refer to the Structural Repair Manual
R (Ref. SRM 511100 P.Block 001) for damage classification and
R corrective action.
R Subtask 53-21-00-916-050
R B. Application of the Temporary Protection
R (Ref. Fig. 601/TASK 53-21-00-991-020)
R CAUTION : DO NOT APPLY TEMPORARY PROTECTION ON THE OXYGEN SYSTEMS._______
R MAKE SURE THAT THE TEMPORARY PROTECTION DOES NOT GET:
R -ON COMPOSITE PARTS, CONTROL CABLES, PULLEYS,TEFLON BEARINGS.
R -ON LUBRICATED SURFACES.
R -IN DRAIN VALVES OR OTHER ORIFICES.
R TEMPORARY PROTECTION ON OR IN THESE PARTS CAN CAUSE DAMAGE.
R (1) Put masking paper or masking tape BONDING AND ADHESIVE COMPOUNDS
R (Material No. 08-074) on the equipment and fittings adjacent to the
R area.
R (2) Apply a layer of STORAGE PRESERVATION (Material No. 15-005) or
R STORAGE PRESERVATION (Material No. 15-006) on the inspection area.
R (3) Remove the masking paper or masking tape.
R 5. Close-up________
R Subtask 53-21-00-410-058
R A. Close Access
R (1) Make sure that the work area is clean and clear of tool(s) and other
R items.
R (2) Install the insulation blankets (Ref. TASK 25-80-00-400-001).
R (3) Install the overhead stowage compartments, if removed.
CES
R (4) Install the ceiling panels (Ref. TASK 25-23-41-400-001).
R (5) Install the cove light panels 231CX, 231FX, 231RX, 232CX, 232FX,
R 232RX (Ref. TASK 25-23-48-400-001).
R (6) Install the sidewall panels 231AX, 232AX, 231PX, 232PX, 231BX, 232BX,
R 231QX, 232QX (Ref. TASK 25-23-43-400-001).
R (7) Install the door frame linings (Ref. TASK 25-23-47-400-004)
R (Ref. TASK 25-23-47-400-009).
R (8) Close the forward emergency exit door 833 (843) (Ref. TASK 52-22-00-
R 410-001).
R (9) Remove the access platform(s).
R TASK 53-21-00-200-019
R Detailed Inspection of Door Stop Fittings on FR 35.1 and FR 35.2A, LH/RH R 1. Reason for the Job
__________________ R Refer to the MPD TASK: 532114-01 R 2. Job Set-up Information
______________________
R A. Fixtures, Tools, Test and Support Equipment
R -------------------------------------------------------------------------------R REFERENCE QTY DESIGNATION