(2)
Install the insulation blankets (Ref. TASK 25-80-00-400-001).
(3)
Install the cargo-compartment floor panels 131EF, 131HF (Ref. TASK 53-22-14-400-001).
(4)
Install the insulation blankets and the sidewall panels 132KW, 132MW, 132QW, 132LW, 131HW, 131MW, 131QW.
**ON A/C ALL
Subtask 53-21-00-942-063
B. Close Access WARNING : MAKE SURE THAT THE TRAVEL RANGES OF THE ELEVATORS ARE CLEAR
_______
DURING CARGO COMPARTMENT DOOR OPERATION.
(1)
Close the forward cargo compartment door 825 (Ref. TASK 52-30-00-860-002)
(2)
Remove the access platform(s).
**ON A/C 301-399,
TASK 53-21-00-200-022
Detailed Inspection of Forward Emergency Exit Skin Cutout, Upper Corners, External Surface, LH
1. Reason for the Job
__________________
Refer to the MPD TASK: 532150-01
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific access platform 3.2 m (10 ft. 6 in.)
B. Consumable Materials
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 11-004 USA MIL-T-81533 1.1.1TRICHLOROETHANE (METHYL CHLOROFORM) (Ref. 20-31-00)
Material No. 19-003 USA AMS 3819 LINT-FREE COTTON CLOTH (Ref. 20-31-00)
C. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
52-22-00-010-002 Opening of the Emergency Exit Doors from the Outside 52-22-00-410-002 Closing of the Emergency Exit Doors from the Outside SRM 511100 P.Block 001 (for corrective action) SRM 512200 P.Block 001 (for corrective action) 53-21-00-991-024 Fig. 617
EFF : 301-399, 53-21-00Page 686
May 01/05
R
CES
3. Job Set-up
__________
Subtask 53-21-00-010-065
A. Get Access
(1)
Put an access platform in position at the zone 231.
(2)
Open the forward emergency exit 833 (Ref. TASK 52-22-00-010-002).
Subtask 53-21-00-110-062
B. Cleaning of the Structure
WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL
_______ MATERIALS ONLY WITH A GOOD SUPPLY OF AIR. OBEY THE MANUFACTURERS INSTRUCTIONS. PUT ON PROTECTIVE CLOTHING. DO NOT GET THEM IN YOUR MOUTH. DO NOT SMOKE. DO NOT BREATHE THE GAS. THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN IRRITANT. GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.
WARNING : OBEY THE MANUFACTURER'S INSTRUCTIONS WHEN YOU USE THIS/THESE
_______ MATERIAL/S. USE PROTECTIVE CLOTHING, RUBBER GLOVES, GOGGLES AND A MASK.
(1) Clean the inspection area with CLEANING AGENTS (Material No. 11-004) and a lint-free cotton cloth MISCELLANEOUS (Material No. 19-003), if necessary.
4. Procedure
_________
Subtask 53-21-00-220-054
A. Inspection
(Ref. Fig. 617/TASK 53-21-00-991-024)
(1) Do a detailed inspection of the external structure of the upper corners of the forward emergency exit skin cutout. This inspection is applicable from FR35.1 to FR35.2A, left side.
Forward Emergency Exit, Upper Corners - External Surface, Left Side Figure 617/TASK 53-21-00-991-024
R EFF : 301-399, 53-21-00Page 688 May 01/05
CES (2) Make sure that there is no:
(a)
Corrosion damage:
-If you find corrosion damage, refer to the Structural Repair Manual (Ref. SRM 512200 P.Block 001) for types of corrosion, inspection, removal and corrosion protection.
(b)
Other damage (cracks, scratches, stress, marks, dents, bumps,...):
-If you find other damage, refer to the Structural Repair Manual (Ref. SRM 511100 P.Block 001) for damage classification and corrective action.
5. Close-up
________
Subtask 53-21-00-410-064
A. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Close the forward emergency exit 833 (Ref. TASK 52-22-00-410-002).
(3)
Remove the access platform(s).
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FUSELAGE 机身1(152)