C. Close Access
(1)
Remove the warning notice(s).
(2)
Remove the plastic bag from the radome.
(3)
Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(4)
Close the radome (Ref. TASK 53-15-11-410-001).
(5)
Remove the access platform(s).
EFF : ALL
53-15-11Page 420
TASK 53-15-11-000-002
Removal of a Radome Telescopic Rod
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific circuit breaker(s) safety clip(s) No specific lifting equipment No specific plastic bag No specific warning notice No specific access platform 3.5 m (11 ft. 6 in.) 98D53103500000 1 SLING-RADOME
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
53-15-11-010-001 Opening of the Radome 110AL 53-15-11-991-001 Fig. 401 53-15-11-991-005 Fig. 408
EFF : ALL
53-15-11Page 421
May 01/05
R
CES 3. Job Set-up
__________
Subtask 53-15-11-865-055
A. Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
121VU COM NAV/RADAR/1 5SQ1 K13
R **ON A/C 051-099,
R 121VU COM NAV/RADAR/2 5SQ2 K14 R **ON A/C ALL
Subtask 53-15-11-941-053
B. Get Access
(1)
Put the access platform in position in the zone 110 in front of the radome.
(2)
In the cockpit put a warning notice in position to tell persons not to operate the radar system.
(3)
Open the radome (Ref. TASK 53-15-11-010-001).
Subtask 53-15-11-620-051
C. Protection of the Radome.
(1)
Put a plastic bag on the radome.
Subtask 53-15-11-420-054
D. Installation of the Radome Sling.
(1)
Install the SLING-RADOME (98D53103500000) (42) on the radome. (Ref. Fig. 401/TASK 53-15-11-991-001)
(2)
Attach the ends of the sling to the housings of the handles (41) and to the hinge fittings.
(3)
Put the lifting equipment with a capacity of 50 kg (110.2311 lb) in position.
(4)
Put the SLING-RADOME (98D53103500000) (42) under tension.
4. Procedure
_________ Subtask 53-15-11-020-051
A. Removal of the Component.
(Ref. Fig. 408/TASK 53-15-11-991-005)
CAUTION : MAKE SURE YOU DO NOT DAMAGE THE ANTENNA.
_______
(1)
Remove the cotter pin (7) and discard it.
(2)
Remove the nut (6) and the washer (5).
(3)
Remove the bolt (3).
(4)
Remove the rod (4) from the support (14).
(5)
Remove the cotter pin (9) and discard it.
(6)
Remove the nut (8).
(7)
Remove the bolt (2).
(8)
Remove the rod (4) form the support (1).
EFF : ALL
53-15-11Page 423
May 01/05
R
CES
Radome Figure 408/TASK 53-15-11-991-005
R EFF : CES ALL 53-15-11 Page 424 Aug 01/02
TASK 53-15-11-400-002
Installation of a Radome Telescopic Rod
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific warning notice
B. Consumable Materials
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 04-004 USA MIL-PRF-23827 TYPE I SYNTH.ESTER BASED GREASE HIGH PRESSURE (Ref. 20-31-00)