NOTE : Only one damage area is permitted.
____
(b) If the distance between the damage and the monolithic area is less than 200 mm (7.8740 in.):
-Immediately remove (Ref. TASK 53-15-11-000-001) and send the radome to a repair station.
-Install a new radome (Ref. TASK 53-15-11-400-001).
(6) Close the radome (Ref. TASK 53-15-11-410-001).
5. Close-up
________
Subtask 53-15-11-865-054
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s): R 5SQ1, 5SQ2.
Subtask 53-15-11-942-052
B. Close Access
(1)
Remove the warning notice(s).
(2)
Close the forward avionics-compartment door 811 (Ref. TASK 52-41-00-410-002).
(3)
Remove the access platform(s).
(4)
De-energize the ground service network (Ref. TASK 24-42-00-862-001).
EFF : ALL
53-15-11Page 615
RADOME (1560WM) - REPAIRS
_________________________
TASK 53-15-11-300-001 Temporary Repair of the Radome
1. Reason for the Job
__________________
Self explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific access platform 3.5 m (11 ft. 6 in.)
B. Consumable Materials
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 05-065 C Z-24.380
EROSION PROTECTIVE TAPE (Ref. 20-31-00) Material No. 11-026D F ASN 42202
GENERAL CLEANING AGENT - MULTI PURPOSE
(Ref. 20-31-00)
Material No. 19-003 USA AMS 3819 LINT-FREE COTTON CLOTH (Ref. 20-31-00)
C. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
53-15-11-991-018 Fig. 801
EFF : ALL
53-15-11Page 801
3. Job Set-up
__________
Subtask 53-15-11-941-061
A. Get Access
(1) Put an access platform in position at the zone 110.
4. Procedure_________
Subtask 53-15-11-350-050
A. Temporary repair
WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL_______ MATERIALS ONLY WITH A GOOD SUPPLY OF AIR. OBEY THE MANUFACTURERS INSTRUCTIONS. PUT ON PROTECTIVE CLOTHING. DO NOT GET THEM IN YOUR MOUTH. DO NOT SMOKE. DO NOT BREATHE THE GAS. THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN IRRITANT. GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.
R R R R (1) For all types of radome (KEVLAR radome: P/N D5311047700001, P/N D5311047700002, P/N D5311047700003, P/N D5311047700004, P/N D5311047700005; QUARTZ radome: P/N D5311047700006, P/N D5311047700007, P/N D53132010000) with SPECIAL MATERIALS (Material No. 05-065) or Polyurethane Adhesive Tape (Supplier/Ref. 8672) (Ref. Fig. 801/TASK 53-15-11-991-018)
(a) Clean the damage area and remove the grease with a clean lint-free cotton cloth MISCELLANEOUS (Material No. 19-003) soaked with CLEANING AGENTS (Material No. 11-026D).
(b) Apply SPECIAL MATERIALS (Material No. 05-065) or Polyurethane Adhesive Tape (Supplier 3M/Ref. 8672) to the repair area.
NOTE : The repair does not change the radio electric, mechanical____ and erosion resistance performance.
EFF : ALL
53-15-11Page 802
Temporary Repair of the Radome
Figure 801/TASK 53-15-11-991-018
EFF : ALL 53-15-11 Page 803
Aug 01/03
CES
R R R (2) For QUARTZ radome only (P/N D5311047700006, P/N D5311047700007, P/N D53132010000) with White or Grey Self-Adhesive Patch Dia. 50 mm (1.9685 in.) (Supplier ADHETEC/Ref. 5015BC or 5015GC)
(a) Clean the damage area and remove the grease with a clean lint-free cotton cloth MISCELLANEOUS (Material No. 19-003) soaked with CLEANING AGENTS (Material No. 11-026D).
(b) Apply a White or Grey Self-Adhesive Patch Dia. 50 mm (1.9685 in.) (Supplier ADHETEC/Ref. 5015BC or 5015GC) to the repair area.
NOTE : The repair does not change the radio electric, mechanical____ and erosion resistance performance.
NOTE : The maximum number of patches is 25 for a radome.____ The minimum distance between every patch is 100 mm (3.9370 in.). An overlap is permitted between the two patches.