EFF : ALL
53-11-00Page 624
May 01/03
R Fuselage Side Panel below Cockpit Side Windows - External Surface R Figure 606/TASK 53-11-00-991-079
EFF : ALL
53-11-00Page 625
May 01/03 CES
R (b) Other damage (cracks, scratches, stress, marks, dents,
R bumps,...):
R - If you find other damage, refer to the Structural Repair Manual
R (Ref. SRM 511100 P.Block 001) for damage classification and
R corrective action.
R 5. Close-up________
R Subtask 53-11-00-942-093
R A. Close Access
R (1) Make sure that the work area is clean and clear of tool(s) and other
R items.
R (2) Remove the access platform(s).
EFF : ALL
53-11-00Page 626
May 01/03
R TASK 53-11-00-210-811
R General Visual Inspection of Area Forward of Windshield, above Side Panel, from
R FR 0 to FR 4, External Surface, LH/RH
R 1. Reason for the Job__________________
R Refer to the MPD TASK: 531118-01
R 2. Job Set-up Information______________________
R A. Fixtures, Tools, Test and Support Equipment
R -------------------------------------------------------------------------------
R REFERENCE QTY DESIGNATION
R -------------------------------------------------------------------------------
R No specific access platform 3.5 m (11 ft. 6 in.)
R B. Consumable Materials
R -------------------------------------------------------------------------------
R REFERENCE DESIGNATION
R -------------------------------------------------------------------------------
R Material No. 11-004 USA MIL-T-81533
R 1.1.1TRICHLOROETHANE (METHYL CHLOROFORM)
R (Ref. 20-31-00)
R Material No. 19-003 USA AMS 3819
R LINT-FREE COTTON CLOTH (Ref. 20-31-00)
R C. Referenced Information
R -------------------------------------------------------------------------------
R REFERENCE DESIGNATION
R -------------------------------------------------------------------------------
R SRM 511100 P.Block 001 (for corrective action)
R SRM 512200 P.Block 001 (for corrective action)
R 53-11-00-991-080 Fig. 607
EFF : ALL
53-11-00Page 627
May 01/03
R 3. Job Set-up__________
R Subtask 53-11-00-941-087
R A. Get Access
R (1) Put an access platform in position at the zones 211 and 212.
R Subtask 53-11-00-110-117
R B. Cleaning of the Structure
R WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL_______
R MATERIALS ONLY WITH A GOOD SUPPLY OF AIR.
R OBEY THE MANUFACTURERS INSTRUCTIONS.