R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
(Ref. Fig. 501/TASK 28-24-00-991-002)
**ON A/C 301-399,
(Ref. Fig. 501A/TASK 28-24-00-991-002-A)
**ON A/C ALL
(Ref. Fig. 502/TASK 28-24-00-991-001)
Subtask 28-24-00-720-058
A. Test of the Valve 12QM
(1) In the test that follows, on each operation of the LP valve:
-
make sure that the see/feel indicator operates smoothly, from the valve open (valve closed) position to the valve closed (valve open) position
-
make sure that the see/feel indicator marks are accurately aligned in the valve open position
-
make sure that the see/feel indicator marks are at 90 degrees to each other in the valve closed position.
1EFF : ALL 1 28-24-00Page 523 1 1 Aug 01/05 1 1 1CES 1 (2) For the valve 12QM, do this test:
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the panel 121VU:
- open, safety and tag the The ENG 1 LP valve MOTOR 2 SUPPLY and
circuit breaker 3QG. CONTROL are isolated.
2. On the ECAM CP: On the ECAM lower DU:
- push (in) the FUEL P/BSW. - the FUEL system page shows
- the LEFT LP valve indication shows
the valve closed (amber cross-line).
3. On the LP valve actuator 9QG:
- look at the position of the The indicator shows that the valve is
mechanical see/feel indicator. closed.
4. On the panel 115VU: On the ECAM lower DU:
- put the ENG/MASTER 1 switch to - the LEFT LP valve indication shows
the ON position. the valve open (green in-line).
5. On the LP valve actuator 9QG:
- look at the position of the The indicator shows that the valve is
see/feel indicator. open.
6. On the panel 115VU: On the ECAM lower DU:
- put the ENG/MASTER 1 switch to - the LEFT LP valve indication shows
the OFF position. the valve closed (amber cross-line).
7. On the LP valve actuator 9QG:
- look at the position of the The indicator shows that the valve is
mechanical see/feel indicator. closed.
8. On the panel 121VU:
- remove the safety clip and the The ENG 1 LP valve MOTOR 2 SUPPLY and
tag and close the circuit CONTROL are energised.
breaker 3QG.
1EFF : ALL 1 28-24-00Page 524 1 1 May 01/04R 1 1 1CES 1
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
9.
On the panel 49VU:
- open, safety and tag the circuit breaker 1QG.
10.
On the panel 115VU:
-put the ENG/MASTER 1 switch to the ON position:
11.
On the LP valve actuator 9QG:
-look at the position of the mechanical see/feel indicator.
12.
On the panel 115VU:
-put the ENG/MASTER 1 switch to the OFF position.
13.
On the LP valve actuator 9QG:
-look at the position of the mechanical see/feel indicator.
14.
On the panel 49VU:
-remove the safety clip and the tag and close the circuit breaker 1QG.
The ENG 1 LP valve MOTOR 1 SUPPLY andCONTROL are isolated.
On the ECAM lower DU:
-
the LEFT LP valve indication shows the valve closed (amber cross-line).
On the ECAM lower DU:
-
the LEFT LP valve indication showsthe valve open (green in-line).
The indicator shows that the valve isopen.
On the ECAM lower DU:
-the LEFT LP valve indication showsthe valve closed (amber cross-line).
The indicator shows that the valve isclosed.
The ENG 1 LP valve MOTOR 1 SUPPLY andCONTROL are energised.
1EFF : ALL 1 28-24-00Page 525 1 1 May 01/04R 1 1 1CES 1
Subtask 28-24-00-720-059
B. Test of the Valve 13QM
(1)
In the test that follows, on each operation of the LP valve:
-
make sure that the see/feel indicator operates smoothly, from the valve open (valve closed) position to the valve closed (valve open) position
-
make sure that the see/feel indicator marks are accurately aligned in the valve open position
-
make sure that the see/feel indicator marks are at 90 degrees to each other in the valve closed position.
(2)
中国航空网 www.aero.cn
航空翻译 www.aviation.cn