 Self Explanatory


 2.
 Job Set-up Information


______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific blanking caps
 No specific circuit breaker(s) safety clip(s)
 No specific access platform 2.0 m (6 ft. 7 in.)

 B. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
32-12-00-010-001 Open the Main Gear Doors for Access 28-25-53-991-001 Fig. 401
 3. Job Set-up
__________ Subtask 28-25-53-941-051
 A. Make sure that on the refuel/defuel control panel 800VU:
 -
the REFUEL switch is in the OFF position,

 -
the OPEN light is off.


 1EFF : ALL 1 28-25-53Page 401 1 1 Feb 01/98 1 1 1CES 1 Subtask 28-25-53-865-050


 B. Open, safety and tag this(these) circuit breaker(s):
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------121VU FUEL/RFL/DFL/SPLY 2QU L24 121VU FUEL/RFL/DFL/XFR/DEFUEL/VALVE 1QU L23
 Subtask 28-25-53-010-051
 C. Get Access
 (1)
 Open the MLG doors (Ref. TASK 32-12-00-010-001)

 (2)
 Open the access door 192MB to get access to the refuel/defuel panel 800VU.

 (3)
 Put the access platform in position at the main landing-gear door.


 4. Procedure
_________ (Ref. Fig. 401/TASK 28-25-53-991-001) Subtask 28-25-53-020-052
 A. Removal of the Defuel/Transfer Valve-Actuator (11QU)
 (1)
 Disconnect the electrical connector (6) from the defuel/transfer valve-actuator (5).

 (2)
 Put blanking caps on the disconnected electrical connectors.

 (3)
 Release the screw and remove the V-clamp (3) which attaches the defuel/transfer valve-actuator (5) to the mounting flange (1).

 (4)
 Remove the defuel/transfer valve-actuator (5).

 (5)
 Remove and discard the O-ring (2) from the mounting flange (1).

 (6)
 Put a blanking cap on the mounting flange (1) and on the
 defuel/transfer valve actuator (5).

 

 1EFF : ALL 1 28-25-53Page 402 1 1 Feb 01/98 1 1 1CES 1


 Transfer Defuel-Valve Actuator - Center Tank.
 Figure 401/TASK 28-25-53-991-001
 1EFF :  ALL  1  28-25-53 Page 403 
1  1  Feb 01/98
 1  1
 1CES  1

 

 TASK 28-25-53-400-001
 Installation of the Center-Tank Defuel/Transfer Valve-Actuator (11QU)

 1.
 Reason for the Job

__________________
 Self Explanatory


 2.
 Job Set-up Information


______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
 -------------------------------------------------------------------------------
No specific warning notices
 No specific access platform 2.0 m (6 ft. 7 in.) R No specific Torque Wrench : range 0.00 to 1.20 m.daN R (0.00 to 9.00 lbf.ft)
 B. Consumable Materials
 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
Material No. 04-563 HIGH TEMPERATUREFLUOROSILICONE GREASE (Ref. 20-31-00)
 C. Expendable Parts
 -------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
 -------------------------------------------------------------------------------
0-ring 28-25-03 02 -130
 1EFF : ALL 1 28-25-53Page 404 1 1 May 01/05 1 1 1CES 1


 D. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
 from the External Power 32-12-00-010-001 Open the Main Gear Doors for Access 32-12-00-410-001 Close the Main Gear Doors after Access 28-25-53-991-001 Fig. 401
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FUEL 燃油4(104)