 -push (in) the L TK PUMPS 1 and 2 (R TK PUMPS 1 and 2) P/BSW's and the related CTR TK XFR P/BSW. Make sure that the applicable P/BSW OFF lights go off.
 NOTE : You can defuel the center (transfer) tank without defueling
____ the wing-tank(s) if there is sufficient space (in the wing tank(s)) for the center-tank fuel. If you defuel the wing-tank(s) only, gravity will move the fuel from the center (transfer) tank into the wing-tank(s). This will happen even if the CTR TK XFR P/BSW(s) (on the panel 40VU) are released (out) (control valve(s) closed).
 (2) On the SD FUEL page, monitor the fuel quantity indications. Make sure that the applicable fuel quantity indications and the Fuel On Board (FOB) figures decrease.
 NOTE : When you defuel the LH wing-tank/center (transfer) tank only,
____ a small quantity of fuel will go into the RH wing-tank. Because the crossfeed valve is open, fuel can go through the grooves in the suction bypass valve.
 1EFF : ALL 1 28-25-00Page 315 1 1 May 01/05R 1 1 1CES 1


 (3)
 When the fuel quantity has decreased to the necessary level:

 (a) On the panel 40VU:
 -release (out) the L TK PUMPS 1 and 2 (R TK PUMPS 1 and 2) P/BSW's
 -the related CTR TK XFR P/BSW
 -make sure that the applicable P/BSW OFF lights come on
 -release (out) the MODE SEL P/BSW. Make sure that the MAN light of the MODE SEL P/BSW goes off (center-tank transfer system now in manual control).
 (b) On the SD FUEL page:
 -
make sure that the fuel quantity indications become stable

 -
make sure that the fuel quantity indication for the center (transfer) tank stops decreasing.

 

 (4)
 To defuel the wing-tank(s) and the center (transfer) tank until empty:


 WARNING : MOVE ALL THE FUEL OUT OF THE CENTER TANK BEFORE YOU GET
_______ ACCESS TO A WING TANK. FUEL IN THE CENTER TANK WILL MOVE INTO AN EMPTY WING TANK BY GRAVITY.
 (a) On the panel 40VU:
 1_ Push (in) the MODE SEL P/BSW. Make sure that the MAN light of
 the MODE SEL P/BSW goes off (center-tank transfer system now
 in automatic control).
 NOTE : You can transfer fuel from the center (transfer) tank____
 with the center transfer system in manual control.
 2_ Push (in) the L TK PUMPS 1 and 2 (R TK PUMPS 1 and 2)
 P/BSW(s).
 3_ Push (in) the related CTR TK XFR P/BSW.
 4_ Make sure that the applicable P/BSW OFF lights go off.
 NOTE : You can defuel the center (transfer) tank without____
 defueling the wing-tank(s) if there is sufficient space
 (in the wing-tank(s)) for the center-tank fuel.
 If you defuel the wing-tank(s) only, gravity will move
 the fuel from the center (transfer) tank into the
 wing-tank(s). This will happen even if the CTR TK XFR
 P/BSW(s) (on the panel 40VU) are released (out)
 (control valve(s) closed). 

R 1EFF : 301-399, 1 28-25-00Page 316 1 1 May 01/05 1 1 1CES 1 5 On the ECAM lower DU, monitor the LH(RH) wing-tank and center


_ (transfer) tank fuel quantity.
 6 When the fuel quantity in the LH(RH) wing-tank(s) and center
_ (transfer) tank indicate zero for 2 minutes, on the panel 40VU:
 -
release (out) the L TK PUMPS 1 and 2 (R TK PUMPS 1 and 2) P/BSWs

 -
release (out) the CTR TK L XFR (CTR TK R XFR) P/BSW(s)


 -make sure that the applicable P/BSW OFF lights come on.
 (b) Drain the remaining fuel from the tank (Ref. TASK 28-25-00-650-003).
 **ON A/C ALL
 5. Close-up
________ R **ON A/C 001-049, 052-099, 101-149, 151-199, 201-299, 301-399, 401-499,
 (Ref. Fig. 302/TASK 28-25-00-991-002)
 **ON A/C 051-051,

 (Ref. Fig. 302A/TASK 28-25-00-991-002-A)
 **ON A/C ALL

 (Ref. Fig. 303/TASK 28-25-00-991-003) R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
 (Ref. Fig. 304/TASK 28-25-00-991-004)
 **ON A/C 301-399,

 (Ref. Fig. 304A/TASK 28-25-00-991-004-A)
 1EFF : ALL 1 28-25-00Page 317 1 1 Aug 01/05 1 1 1CES 1 **ON A/C ALL


 Subtask 28-25-00-410-050
 A. Close Access
 (1) Make sure that the work area is clean and clear of tool(s) and other items.
 (2) Close the access door 192MB.
 Subtask 28-25-00-862-050

 B. De-energize the Electrical Circuits
 (1) De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-002).

R **ON A/C 001-049, 052-099, 101-149, 151-199, 201-299, 301-399, 401-499,
 Subtask 28-25-00-942-074
 C. Removal of Equipment
 (1)
 Remove the safety barriers.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FUEL 燃油4(30)