• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-22 06:55来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者


 Component Location and Detail Figure 502/TASK 28-24-00-991-001
 1EFF : 1 1R 1CES  ALL  1 11 1 28-24-00 Page 512 May 01/04

 

 Subtask 28-24-00-010-050
 B. Get Access
 (1)
 Put the access platform in position.

 (2)
 Remove the applicable access panel(s):
 FOR 12QM

 

 -remove 522AT
 FOR 13QM

 -remove 622AT.
 Subtask 28-24-00-860-060

 C. Aircraft Maintenance Configuration
 (1)
 Make sure that the APU does not operate and there is no bleed air.

 (2)
 Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).


 (3) Do the EIS start procedure (ECAM only) (Ref. TASK 31-60-00-860-001). Subtask 28-24-00-865-068
 D. Make sure that this(these) circuit breaker(s) is(are) closed:
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU FUEL/LP VALVE/MOT1/ENG2 2QG A09
 49VU FUEL/LP VALVE/MOT1/ENG1 1QG A08 121VU FUEL/LP VALVE/MOT2/ENG2 4QG M26 121VU FUEL/LP VALVE/MOT2/ENG1 3QG M25
 4. Procedure
_________ R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
 (Ref. Fig. 501/TASK 28-24-00-991-002)
 **ON A/C 301-399,

 (Ref. Fig. 501A/TASK 28-24-00-991-002-A)
 1EFF : ALL 1 28-24-00Page 513 1 1 Aug 01/05 1 1 1CES 1R **ON A/C ALL

 

R (Ref. Fig. 502/TASK 28-24-00-991-001)
 Subtask 28-24-00-720-050
 A. Test of the Valve 12QM
 (1)
 In the test that follows, on each operation of the LP valve:

 -
make sure that the see/feel indicator operates smoothly, from the valve open (valve closed) position to the valve closed (valve open) position

 -
make sure that the see/feel indicator marks are accurately aligned in the valve open position

 -
make sure that the see/feel indicator marks are at 90 degrees to each other in the valve closed position.

 

 (2)
 For the valve 12QM, do this test:


 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1.
 On the panel 121VU:

 - open, safety and tag the circuit breaker 3QG.

2.
 On the ECAM CP:

-push (in) the FUEL P/BSW.

3.
 On the LP valve actuator 9QG:

 -look at the position of the mechanical see/feel indicator.

4.
 On the panel 115VU:

-put the ENG/MASTER 1 switch to the ON position.

5.
 On the LP valve actuator 9QG:


The ENG 1 LP valve MOTOR 2 SUPPLY andCONTROL are isolated.
On the ECAM lower DU:
-
the FUEL system page shows

 -
the LEFT LP valve indication shows the valve closed (amber cross-line).


The indicator shows that the valve isclosed.
On the ECAM lower DU:
-the LEFT LP valve indication showsthe valve open (green in-line).
 1EFF : ALL 1 28-24-00Page 514 1 1 May 01/04 1 1 1CES 1


 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
-look at the position of the see/feel indicator.
6. On the panel 115VU:
-put the ENG/MASTER 1 switch to the OFF position.
7. On the LP valve actuator 9QG:
 -look at the position of the mechanical see/feel indicator.
8. On the panel 121VU:
 -remove the safety clip and the tag and close the circuit breaker 3QG.
 9.
 On the panel 49VU:

 - open, safety and tag the circuit breaker 1QG.

10.
 On the panel 115VU:

-put the ENG/MASTER 1 switch to the ON position:

11.
 On the LP valve actuator 9QG:

 -look at the position of the mechanical see/feel indicator.

12.
 On the panel 115VU:


-put the ENG/MASTER 1 switch to the OFF position.
The indicator shows that the valve isopen.
On the ECAM lower DU:
-the LEFT LP valve indication showsthe valve closed (amber cross-line).
The indicator shows that the valve isclosed.
The ENG 1 LP valve MOTOR 2 SUPPLY andCONTROL are energised.
The ENG 1 LP valve MOTOR 1 SUPPLY andCONTROL are isolated.
 On the ECAM lower DU:
 -
the LEFT LP valve indication shows the valve closed (amber cross-line).

On the ECAM lower DU:

-
the LEFT LP valve indication showsthe valve open (green in-line).
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FUEL 燃油4(3)