Component Location and Detail Figure 502/TASK 28-24-00-991-001
1EFF : 1 1R 1CES ALL 1 11 1 28-24-00 Page 512 May 01/04
Subtask 28-24-00-010-050
B. Get Access
(1)
Put the access platform in position.
(2)
Remove the applicable access panel(s):
FOR 12QM
-remove 522AT
FOR 13QM
-remove 622AT.
Subtask 28-24-00-860-060
C. Aircraft Maintenance Configuration
(1)
Make sure that the APU does not operate and there is no bleed air.
(2)
Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).
(3) Do the EIS start procedure (ECAM only) (Ref. TASK 31-60-00-860-001). Subtask 28-24-00-865-068
D. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU FUEL/LP VALVE/MOT1/ENG2 2QG A09
49VU FUEL/LP VALVE/MOT1/ENG1 1QG A08 121VU FUEL/LP VALVE/MOT2/ENG2 4QG M26 121VU FUEL/LP VALVE/MOT2/ENG1 3QG M25
4. Procedure
_________ R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
(Ref. Fig. 501/TASK 28-24-00-991-002)
**ON A/C 301-399,
(Ref. Fig. 501A/TASK 28-24-00-991-002-A)
1EFF : ALL 1 28-24-00Page 513 1 1 Aug 01/05 1 1 1CES 1R **ON A/C ALL
R (Ref. Fig. 502/TASK 28-24-00-991-001)
Subtask 28-24-00-720-050
A. Test of the Valve 12QM
(1)
In the test that follows, on each operation of the LP valve:
-
make sure that the see/feel indicator operates smoothly, from the valve open (valve closed) position to the valve closed (valve open) position
-
make sure that the see/feel indicator marks are accurately aligned in the valve open position
-
make sure that the see/feel indicator marks are at 90 degrees to each other in the valve closed position.
(2)
For the valve 12QM, do this test:
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1.
On the panel 121VU:
- open, safety and tag the circuit breaker 3QG.
2.
On the ECAM CP:
-push (in) the FUEL P/BSW.
3.
On the LP valve actuator 9QG:
-look at the position of the mechanical see/feel indicator.
4.
On the panel 115VU:
-put the ENG/MASTER 1 switch to the ON position.
5.
On the LP valve actuator 9QG:
The ENG 1 LP valve MOTOR 2 SUPPLY andCONTROL are isolated.
On the ECAM lower DU:
-
the FUEL system page shows
-
the LEFT LP valve indication shows the valve closed (amber cross-line).
The indicator shows that the valve isclosed.
On the ECAM lower DU:
-the LEFT LP valve indication showsthe valve open (green in-line).
1EFF : ALL 1 28-24-00Page 514 1 1 May 01/04 1 1 1CES 1
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
-look at the position of the see/feel indicator.
6. On the panel 115VU:
-put the ENG/MASTER 1 switch to the OFF position.
7. On the LP valve actuator 9QG:
-look at the position of the mechanical see/feel indicator.
8. On the panel 121VU:
-remove the safety clip and the tag and close the circuit breaker 3QG.
9.
On the panel 49VU:
- open, safety and tag the circuit breaker 1QG.
10.
On the panel 115VU:
-put the ENG/MASTER 1 switch to the ON position:
11.
On the LP valve actuator 9QG:
-look at the position of the mechanical see/feel indicator.
12.
On the panel 115VU:
-put the ENG/MASTER 1 switch to the OFF position.
The indicator shows that the valve isopen.
On the ECAM lower DU:
-the LEFT LP valve indication showsthe valve closed (amber cross-line).
The indicator shows that the valve isclosed.
The ENG 1 LP valve MOTOR 2 SUPPLY andCONTROL are energised.
The ENG 1 LP valve MOTOR 1 SUPPLY andCONTROL are isolated.
On the ECAM lower DU:
-
the LEFT LP valve indication shows the valve closed (amber cross-line).
On the ECAM lower DU:
-
the LEFT LP valve indication showsthe valve open (green in-line).
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FUEL 燃油4(3)