7. Operation/Control and Indication
________________________________
(Ref. Fig. 003)
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
(Ref. Fig. 006)
R **ON A/C 106-149, 401-499,
(Ref. Fig. 006A)
**ON A/C 301-302,
(Ref. Fig. 006B)
**ON A/C 303-399,
(Ref. Fig. 006C)
**ON A/C ALL
A. Normal Operation
(1)
The APU Fuel Supply When the APU MASTER SW is set to on, the ECB energizes the APU MAIN RELAY 4KD. It energizes the APU fuel LP valve-actuator 3QF and the APU fuel LP valve 14QM opens. Then the engine pump or APU fuel pump supply the necessary fuel from the engine feed line to the APU fuel distribution system.
(2)
APU Shutdown When the APU shuts down, the ECB de-energizes the APU MAIN RELAY 4KD. It de-energizes the APU fuel LP valve-actuator 3QF and the APU fuel LP valve 14QM closes. The APU MAIN RELAY 4KD de-energizes the APU fuel feed pump 4QC if it was in operation.
(3)
APU Fuel-Feed Pump Operation for Ground Maintenance The vent APU fuel line pushbutton switch 8QC permits the APU fuel-feed pump 4QC to operate on the ground (to purge the APU fuel-feed line during ground maintenance). When you operate the VENT APU FUEL LINE pushbutton switch 8QC:
-the APU fuel line vent relay 6QC energizes,
1EFF : ALL 1 28-29-00Page 12 1 1 Aug 01/05 1 1 1CES 1
ECAM Location and Typical Displays
Figure 006
R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 28-29-00Page 13 1201-299, 1May 01/05 1 1 1CES 1
ECAM Location and Typical Displays
Figure 006A
R 1EFF : 106-149, 401-499, 1 28-29-00Page 14 1 1 Aug 01/05 1 1 1CES 1
ECAM Location and Typical Displays
R Figure 006B
R 1EFF : 301-302, 1 28-29-00 Page 15
1 1 May 01/05
1 1
1CES 1
ECAM Location and Typical Displays
R Figure 006C
R 1EFF : 303-399, 1 28-29-00 Page 16
1 1 May 01/05
1 1
1CES 1
-
the actuator fuel LP valve 3QF energizes and opens the APU fuel LP valve 14QM,
-
the ESSENTIAL AC BUS 1 401XP supplies 115VAC single-phase to
operate the motor of the APU fuel-feed pump 4QC. The pump will continue to operate and the valve will stay open as long as the pushbutton is pushed. When the pushbutton is released the pump will stop and the valve will close.