REFERENCE DESIGNATION
-------------------------------------------------------------------------------
31-60-00-860-002 EIS Stop Procedure
28-25-00-991-024 Fig. 403
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
28-25-00-991-025 Fig. 405
**ON A/C 301-399,
28-25-00-991-025-A Fig. 405A
**ON A/C ALL
3. Job Set-up
__________
(Ref. Fig. 403/TASK 28-25-00-991-024)
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
(Ref. Fig. 405/TASK 28-25-00-991-025)
**ON A/C 301-399,
(Ref. Fig. 405A/TASK 28-25-00-991-025-A)
**ON A/C ALL
Subtask 28-25-00-941-083
A. Safety Precautions
WARNING : OBEY THE FUEL SAFETY PROCEDURES.
_______
(1)
You must obey the safety procedures when you do work on the fuel system (Ref. TASK 28-00-00-910-001).
(2)
Put the safety barriers in position.
1EFF : ALL 1 28-25-00Page 438 1 1 Aug 01/05 1 1 1CES 1
ECAM Displays and Control Panel
Figure 405/TASK 28-25-00-991-025
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 28-25-00Page 439 1201-299, 401-499, 1Aug 01/05 1 1 1CES 1
ECAM Displays and Control Panel
Figure 405A/TASK 28-25-00-991-025-A
R 1EFF : 301-399, 1 28-25-00 Page 440
1 1 May 01/05
1 1
1CES 1
(3) Put a warning notice in position to tell persons not to operate the MLG doors.
R **ON A/C 001-049, 052-099, 101-149, 151-199, 201-299, 301-399, 401-499,
Subtask 28-25-00-010-081
B. Get Access
(1) Open the access door 192MB.
(2) Put an access platform in position below the refuel/defuel coupling. Subtask 28-25-00-860-067
C. Aircraft Maintenance Configuration
(1) Make sure that the aircraft and the fuel tanker/pump unit are grounded correctly (Ref. TASK 12-34-24-869-001).
NOTE : Bonding is essential, grounding is recommended.
____
(2)
Make sure that the chocks do not touch the tires. The weight of the fuel can lower the aircraft and cause the chocks to catch.
(3)
Remove the refuel/defuel coupling-cap 41QM.
(4)
Make sure that the hose-coupling of the fuel tanker/pump unit is clean.
(5)
Connect the hose-coupling of the fuel tanker/pump unit to the aircraft refuel/defuel coupling.
(6)
Set the fuel tanker/pump unit to the refuel mode.
(7)
Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).
(8)
Do the EIS start procedure (ECAM only) (Ref. TASK 31-60-00-860-001).
(9)
On the ECAM CP, push (in) the FUEL system page pushbutton switch. Make sure that the FUEL page is shown on the ECAM lower DU.
1EFF : ALL 1 28-25-00Page 441 1 1 Aug 01/05 1 1 1CES 1 1EFF : 051-051, 1 28-25-00Page 442 1 1 May 01/05 1 1 1CES 1 **ON A/C ALL
R **ON A/C 051-051,
R Subtask 28-25-00-010-081-A
R B. Get Access
R (1) Put the access platform in position below the applicable access panel
R 522KB.
R (2) Open the access door 522KB.
R Subtask 28-25-00-860-067-A
R C. Aircraft Maintenance Configuration
R (1) Make sure that the aircraft and the fuel tanker/pump unit are
R grounded correctly (Ref. TASK 12-34-24-869-001).
R NOTE : Bonding is essential, grounding is recommended.____
R (2) Make sure that the chocks do not touch the tires. The weight of the
R fuel can lower the aircraft and cause the chocks to catch.
R (3) Remove the refuel/defuel coupling-cap 101QM(41QM).
R (4) Make sure that the hose-coupling of the fuel tanker/pump unit is
R clean.
R (5) Connect the hose-coupling of the fuel tanker/pump unit to the
R aircraft refuel/defuel coupling.
R (6) Set the fuel tanker/pump unit to the refuel mode.
R (7) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-
R 002).
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FUEL 燃油4(48)