4. Procedure
_________
(Ref. Fig. 401/TASK 28-24-41-991-001) Subtask 28-24-41-560-050
A. Preparation for a Replacement Component
(1) Install the nut (13) and the circlip (4). Subtask 28-24-41-420-052
B. Preparation for Installation
WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL
_______ MATERIALS ONLY WITH A GOOD SUPPLY OF AIR. OBEY THE MANUFACTURERS INSTRUCTIONS. PUT ON PROTECTIVE CLOTHING. DO NOT GET THEM IN YOUR MOUTH. DO NOT SMOKE. DO NOT BREATHE THE GAS. THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN IRRITANT. GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.
(1)
Clean the component interface and/or the adjacent area with a clean MISCELLANEOUS (Material No. 19-003) made moist with CLEANING AGENTS (Material No. 11-026).
(2)
Do an inspection of the component interface and/or the adjacent area.
(3)
Make sure that the parts retained from the removed component are clean and in the correct condition.
(4)
Remove the blanking cap from the end of the pipe (1).
(5)
Apply FUELS (Material No. 01-001) or COMMON GREASE (Material No. 04-012) to the new O-ring (7) then install the new O-ring (7) on the projection of the LP fuel valve (12).
Subtask 28-24-41-420-051
C. Installation of the LP Fuel Valve 12QM(13QM)
(1)
Remove the cap from the mounting plate (8).
(2)
Install the LP fuel valve (12) on the mounting plate (8).
(3)
Install and tighten the bolts (5).
(4)
Apply FUELS (Material No. 01-001) to the new O-ring (2) and the new O-ring (3).
1EFF : ALL 1 28-24-41Page 409 1 1 May 01/04R 1 1 1CES 1
(5)
Install the new O-rings (2) and (3) on the end of the pipe (1).
(6)
Tighten the nut (13) on the connector (14).
(7)
Safety the nuts (13) and (15) with MISCELLANEOUS (Material No. 19-010).
(8)
Install the bonding strips (6) and (10), the bolt (11) and the nut
(9) (Ref. TASK 20-28-00-912-004).
(9)
Install the LP fuel-valve actuator (Ref. TASK 28-24-51-400-001), but do not close the access panel 522AT(622AT).
Subtask 28-24-41-861-051
D. Emergize the Electrical Circuits
(1) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).
Subtask 28-24-41-865-055
E. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 1QA, 1QG, 2QA, 2QG, 3QG, 4QG, 7QA, 8QA, 29QA, 30QA.
Subtask 28-24-41-860-051
F. Aircraft Maintenance Configuration
(1)
Refuel the applicable tank as necessary (Ref. TASK 12-11-28-650-003).
(2)
On panel 40VU:
-
for the left wing, push (in) the L TK PUMPS 1 and 2 pushbutton switches
-
for the right wing, push (in) the R TK PUMPS 1 and 2 pushbutton switches.
Subtask 28-24-41-710-050
G. Test
(1) Do an operational test of the LP fuel valve (Ref. TASK 28-24-00-710-002).
NOTE : Let the LP fuel valve stay open for 10 minutes (to let the
____ fuel get through the LP fuel valve, for the leak check).
1EFF : ALL 1 28-24-41Page 410 1 1 May 01/04R 1 1 1CES 1
(2) Examine these areas for leaks:
-the LP fuel-valve to mounting-plate interface
-after 10 minutes, the pylon drain hole.
5. Close-up
________
Subtask 28-24-41-869-055
A. Aircraft Configuration
(1) On panel 40VU:
-
for the left wing, release (out) the L TK PUMPS pushbutton switches 1 and 2
-
for the right wing, release (out) the R TK PUMPS pushbutton switches 1 and 2.
Subtask 28-24-41-410-053
B. Close Access R
R (1) Install the access panel 522AT(622AT) (Ref. TASK 57-41-37-400-003). Subtask 28-24-41-942-051
C. Removal of Equipment
(1)
Remove the safety barriers.
(2)
Remove the warning notice(s).
(3)
Remove the access platform(s).
(4)
Remove the ground support and maintenance equipment, the special and standard tools and all other items.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn