323 FLIGHT PATH ACCEL  0.02G  335 TRACK ANGLE RATE  4.0`/SEC 
322 FLIGHT PATH ANGLE  -5`  013/313 TRACK ANGLE TRUE *  00.0` 
012/312 GROUND SPEED *  200KTS  317 TRACK ANGLE-MAG  5`
361 INERTIAL ALTITUDE  10,000FT  044/314 TRUE HEADING *  10` 
365 INERTIAL VERT SPD  -600FPM  364 VERTICAL ACCEL  0.16 
370 IRS DISCRETES  NA 1  016/316 WIND DIRECTION-TRUE*  30` 
350 IRS MAINT DISCRETE  NA  015/315 WIND SPEED  100KTS 
277 IRS TEST 

* THESE VALUES CAN BE READ ON INSTRUMENTS AND/OR ISDU
1 BITS 11,13,16 AND 17 ARE SET FOR 2 SECONDS AT START OF TEST
IRS Self Test Values
Figure 23

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITHOUT EFIS ú

 34-28-00

 ú ú 07 Page 50 ú Feb 25/87
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
 1.

2.

3.


A
737-300/400/500MAINTENANCE MANUAL
 INERTIAL REFERENCE SYSTEM - TROUBLE SHOOTING
____________________________________________
General
_______
 A.  There are two procedures to identify malfunctions or failures of the IRS system. One procedure is a continuous monitoring in the IRS that shows failures as malfunction codes. The other procedure is the BITE (Built-In Test Equipment).
IRS Ground Crew Call Horn - Activation and Deactivation
_______________________________________________________
 A.  The inertial reference system (IRS) activates the ground crew call horn when one of these conditions occur:
 (1)  
Equipment Cooling (all of these conditions must occur)

 (a)  
Airplane on the ground

 (b)  
No cooling on the IRU's

 (c)  
IRS AC circuit breaker is closed

 (d)  
IRS is on

 

 (2)  
IRS on DC power (all of these conditions must occur)

 (a)  
Airplane on the ground

 (b)  
IRS AC circuit breaker open or loss of IRS AC power, and DC circuit breaker is closed

 (c)  
IRS is on

 


Accidental IRU Self-test after You Apply Static Inverter Power
______________________________________________________________
 A.  AIRPLANES WITH DAA P/N 10-62042-301-01; there is an undetectable failure that starts the IRS self-test during standby power tests.
 B.  A self-test may be initiated if these conditions occur:
 (1)  
The STANDBY POWER switch on the P5 Overhead panel is moved from the AUTO position to the OFF position.

 (2)  
The switch remains in the OFF position for a short time.

 (3)  
The switch is then moved to the BAT position.


 C.  AIRPLANES WITH DAA P/N 10-62042-301-01; Some of these units are susceptible to slow voltage rises in static inverter power. This slow voltage rise may casue a signal to be sent to the IRU which starts the IRS self-test. This condition occurs when the DAA has its power fully removed and the static inverter power is applied.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITHOUT EFIS ú

 34-28-00
 ú ú 02 Page 101 ú Nov 12/01

BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 D.  The IRU self-test is inhibited when the ground speed is larger than 20 knots. Therefore, this problem will not cause irregular flight compartment indications during flight operation.
 4.  IRS Alignment - Warning, Restoration Procedure
______________________________________________
 A.  Figure 101 lists recommended steps that you should follow when the IRS MSU ALIGN light flashes or if the IRS is in the ATT mode but you want the NAV mode. The recommended steps (shown on the figure) should be followed to restore the alignment process.
 (1)  
Make sure the two ALIGN lights on the IRS MSU are on before you input the present position.

 (2)  
To correct a flashing ALIGN light problem, the present position may be input through the Flight Management Computer (FMC) Control Display Unit (CDU).
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 导航 NAVIGATION 2(33)