(e)
Release the DSPL SEL switch on the ISDU.
E. Put the Airplane Back to Its Usual Condition
S 864-054
CAUTION:_______SOME SWITCHES MUST BE PULLED AND THEN TURNED. IF YOU TRY TO TURN THESE SWITCHES BEFORE YOU PULL THEM, YOU CAN DAMAGE THEM.
(1)
Turn the two switches on the MSU to the OFF position.
(2)
Set the IRS switch on the P5-28 panel to the NORMAL position.
S 864-041
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
34-28-92
ALL ú ú 02 Page 406 ú Nov 15/97
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
(3) S 864-043AIRPLANES WITHOUT EFIS; remove the IRU cooling if it is not necessary (AMM 21-58-00/501).
(4) S 864-045AIRPLANES WITH EFIS; remove the IRU cooling if it is not necessary (AMM 21-58-03/501).
(5) S 864-047AIRPLANES WITH EFIS; stop the cool air to the EHSI's, EADI's and EFIS symbol generators if it is not necessary (AMM 21-58-02/501).
(6) S 864-011Remove electrical power if it is not necessary (AMM 24-22-00/201).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
34-28-92
ALL ú ú 02 Page 407 ú Nov 15/96
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
ATTITUDE TRANSFER RELAY - REMOVAL/INSTALLATION
______________________________________________
1. General_______
A. This procedure contains two tasks. The first task is for the removal of an attitude transfer relay. The second task is for the installation of an attitude transfer relay.
B. The two relays are installed on the E1-2 shelf in the main equipment center. Attitude transfer relay No. 2, R51, is installed above attitude transfer realy No. 1, R67 (Fig. 401).
C. Attitude transfer relay No. 1 is the same as attitude transfer relay No. 2.
TASK 34-28-93-004-001
2. Attitude Transfer Relay Removal_______________________________
A. Access
(1)
Location Zone
205 Electronic Compartment
(2)
Access Panels
1201L Electronic Equipment Access Door
B. Procedure
S 864-002
(1)
Open these circuit breakers and attach DO-NOT-CLOSE tags:
(a)
P6 Circuit Breaker Panel
1) F/O ADI
2) CAPT ADI (ALT)
3) DAA NO. 2 FMC
4) DAA NO. 2 FMC AC
5) DAA NO. 2 IRS AC
6) DAA NO. 2 IRS DC
(b)
P18 Circuit Breaker Panel
1) INSTR XFER
2) CAPT ADI
3) F/O ADI (ALT)
4) DAA NO. 1 FMC
5) DAA NO. 1 FMC AC
6) DAA NO. 1 IRS AC
7) DAA NO. 1 IRS DC
(2)
Remove the screws from the face of the relay.
(3)
Remove the relay from the rack.
S 034-003
S 024-004
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITHOUT EFIS ú
34-28-93
ú ú 02 Page 401 ú Mar 15/92
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
E3 RACK
Attitude Transfer Relay Installation
Figure 401
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITHOUT EFIS ú
34-28-93
ú ú 02 Page 402 ú Mar 15/92
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A05813
A 737-300/400/500MAINTENANCE MANUAL
TASK 34-28-93-404-005
3. Attitude Transfer Relay Installation
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 导航 NAVIGATION 2(102)