(3)
Aluminum Tubular Wire Mesh - Knitted Mesh Tecknit 20-21112, Technical Wire Products, Inc. 427 Olive St., Santa Barbara, Ca. 93101 Tubular Wire Mesh - 5-71761-54, (Equivalent)
NOTE: Tubular wire mesh is needed for PPG and Sierracin windows
____ only. It is not needed for Triplex windows.
(4) Spatula or flow gun
C. Consumable Materials
(1)
G01670 Teflon Tape - 0.010 inch (0.25 mm) x 1 inch (25 mm)
(2)
G00000 (Alternative) Tape - Scotch Cal No. 639 (Ref 20-30-51)
(3)
G00000 Protective covering for windows not already protected -Polyester Transparent Tape, No. 850 (Ref 20-30-51)
(4)
G00000 Masking Tape - No. 221 (Ref 20-30-51)
(5)
A00000 Window Frame Fairing Compound - EC-3587-1/4, EC-3587-1
(6)
B00083 Aliphatic Naphtha - TT-N-95A, Type II (Ref 20-30-31)
NOTE: Freon-TF may be used in lieu of aliphatic naphtha for
____ general cleaning of windows.
(7)
B00000 Corrosion Preventive Compound - MIL-C-11796, Class 3 (Ref 20-30-21)
(8)
G00039 Nylon Cord - MIL-C-5040, Type 1A (Ref 20-30-51)
(9)
A00103 Aerodynamic Smoother - PR 1425 (Ref 20-30-11)
(10)
A00247 (Alternative) BMS 5-95 Class B or Pro Seal 860 Class B (Ref 20-30-11)
CAUTION: DO NOT APPLY PR 1826 TO A WINDOW CONSTRUCTION THAT HAS ACRYLIC.
_______
DAMAGE CAN RESULT IN THE ACRYLIC LAMINATE.
(11) A00707 (Alternative) PR 1826, Class B-1/2 and Class B-1/4 (with primer) (dark grey).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
56-11-11
ú ALL ú
ú ú ú B01.101 ú BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. Page 405Jul 12/02
D.
E.
F.
A 737-300/400/500MAINTENANCE MANUAL
CAUTION: DO NOT APPLY PR 1828 TO A WINDOW CONSTRUCTION THAT HAS ACRYLIC.
_______ DAMAGE CAN RESULT IN THE ACRYLIC LAMINATE.
(12)
A00707 (Alternative) PR 1828, Class B-1/2 and B-1/4 (white).
(13)
G00033 Cheesecloth - lint and oil free
(14)
A00000 Compound, Electrical Insulating Coating - BMS 5-37
(Ref 20-30-11)References
(1)
AMM 25-11-11/201, Flight Compartment Equipment
(2)
AMM 25-11-21/201, Flight Compartment Lining and Insulation
(3)
AMM 30-41-00/501, Control Cabin Window Anti-Icing System
(4)
AMM 30-41-21/501, Window Heat Conductive Coating and Sensor
(5)
AMM 30-42-11/401, Windshield Wiper Assembly
(6)
AMM 56-11-00/801, Control Cabin Fixed Windows
(7)
AMM 56-11-11/601, Window No. 1
(8)
IPC 56-11-11, Fig. 1Access
(1)
Location Zones 101 Control Cabin, Left 102 Control Cabin, Right
Prepare to Install the Window.
S 764-055-B00
WARNING: THE OUTPUT VOLTAGE OF THE AUTOTRANSFORMER RANGES FROM 250 TO
_______ 350 VOLTS. YOU MUST BE CAREFUL WHEN YOU INSTALL THE WINDOW OR YOU CAN CAUSE INJURY TO PERSONS OR DAMAGE TO EQUIPMENT.
(1)
Make sure there is no power in the window heating circuit.
S 434-056-B00
(2)
Put the bolts and the nuts in groups for the installation.
NOTE:____It is recommended that new hardware be installed. If new hardware is not available, the old hardware can be installed if in good condition. Before you can use the old hardware, examine the condition and clean off any contamination.
S 214-016-B00
(3) Examine the leveling compound for the window and repair it if necessary (AMM 56-11-00/801).
NOTE: The spacer will compress the leveling compound on the
____ structure around the end of the spacer. You do not have to repair the compound on subsequent window installations.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
56-11-11
ALL ú ú B01 Page 406 ú Nov 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 WINDOWS(12)