「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : 001-049, 051-099, 101-105, 201-299, ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page A223
Aug 01/05R CES
- do the CIDS BITE test through the MCDU/CFDS (Ref. AMM TASK 23-73-00-740-005).
1 If the CIDS BITE test gives the maintenance message DEU-A
_
200RH24:
- install a new DEU-A (200RH24) (Ref. AMM TASK 23-73-46-400-001).
2 If the CIDS BITE test gives the maintenance message CIDS TOP
_
LINE 1 R:
- install the removed DEU-A (200RH24) (Ref. AMM TASK 23-73-46-400-001).
- do the steps 4. B. (5) (a) again for the subsequent DEUs until the maintenance message stops: (Ref. ASM 23-73/06) DEU-A (200RH20) DEU-A (200RH16) DEU-A (200RH12) DEU-A (200RH8) DEU-A (200RH4)
(b) If there is a short circuit:
- remove the DEU-A (200RH24) (Ref. AMM TASK 23-73-46-000-001)
- do a check for a short circuit again.
1 If there is no short circuit:
_
- install a new DEU-A (200RH24) (Ref. AMM TASK 23-73-46-400-001).
2 If the fault continues:
_
- disconnect the electrical connector 7253VC2 from the DEU mount 2014VU2 (Ref. AMM TASK 23-73-48-000-001).
- do a check for a short circuit again.
a If there is no short circuit:
_
- install a new DEU mount 2014VU2 (Ref. AMM TASK 23-73-48-000-001) and (Ref. AMM TASK 23-73-48-400-001).
b If the fault continues:
_
- remove the DEU-A (200RH20) (Ref. AMM TASK 23-73-46-000-001)
- do a check for a short circuit again.
- b.1. If there is no short circuit:
- install a new DEU-A (200RH20) (Ref. AMM TASK 23-73-46-400-001).
- b.2. If the fault continues:
- install the removed DEU-A (200RH24) (Ref. AMM TASK 23-73-46-400-001),
- reconnect the electrical connector to the DEU mount 2014VU2 (Ref. AMM TASK 23-73-48-400-001),
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : 001-049, 051-099, 101-105, 201-299, ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page A224
Aug 01/05R CES
- disconnect the electrical connector 7213VC20 from the DEU mount 2010VU20 (Ref. AMM TASK 23-73-48-000-001),
- do a check for a short circuit again.
- b.2.1. If there is no short circuit:
- do a check for a short circuit at the connector 7213VC20 between pin 9 and GND (pin 11) and between pin 10 and GND (pin 11).
- b.2.1.1. If there is a short circuit:
- repair the wiring between the DEU mount 2010VU20 and the DEU mount 2014VU2 (Ref. ASM 23-73/06).
- b.2.1.2. If there is no short circuit:
- install a new DEU mount 2010VU20 (Ref. AMM TASK 23-73-48-400-001).
- b.2.2. If there is a short circuit:
- install the removed DEU-A (200RH20) (Ref. AMM TASK 23-73-46-400-001),
- reconnect the electrical connector to the DEU mount 2010VU20 (Ref. AMM TASK 23-73-48-400-001),
- do the steps (4. B. (5) (b) 2 b) again for the subsequent DEUs and DEU mounts until the maintenance message stops: (Ref. ASM 23-73/06) DEU-A (200RH16) and DEU mount 2010VU16, DEU-A (200RH12) and DEU mount 2010VU12, DEU-A (200RH8) and DEU mount 2010VU8, DEU-A (200RH4) and DEU mount 2010VU4,
(6) If the resistance (line to line) is more than 200 ohms (open circuit):
- disconnect the electrical connector 7253VC2 from the DEU mount 2014VU2 (Ref. AMM TASK 23-73-48-000-001),
- make sure that the resistance (line to line) is not more than 200 ohms (open circuit) between: DEU mount 2014VU2 pin A/1 and pin A/2
(a) If there is an open circuit:
- install a new DEU mount 2014VU2 (Ref. AMM TASK 23-73-48-400-001)
(b) If there is no open circuit:
- reconnect the electrical connector to the DEU mount 2014VU2 (Ref. AMM TASK 23-73-48-400-001)
- disconnect the electrical connector 7213VC4 from the DEU mount 2010VU4 (Ref. AMM TASK 23-73-48-000-001),
- do a check of the wiring (continuity-check) between: DIR-CIDS (101RH) connector AA/A15 and the connector 7213VC4 pin A/1, DIR-CIDS (101RH) connector AA/B15 and the connector 7213VC4 pin A/2.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 201-299, ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page A225
Aug 01/05 CES 1 If there is no continuity: