- do the CIDS Interface and Power-Up test through the CFDS (Ref. AMM TASK 23-73-00-740-010)
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : ALL ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page A292
Aug 01/05 CES (1) If the fault continues:
- replace the FAP (120RH) (Ref. AMM TASK 23-73-12-000-007) and (Ref. AMM TASK 23-73-12-400-007)
(a) If the fault continues:
- do a check and repair the wiring between: DIR-CIDS (101RH) connector AA/5A and FAP <NAME> (120RH) connector A/1, DIR-CIDS (101RH) connector AA/5B and FAP (120RH) connector A/2, DIR-CIDS (101RH) connector AA/13C and FAP (120RH) connector A/3, DIR-CIDS (101RH) connector AA/13D and FAP (120RH) connector A/4, CB 170RH and FAP <NAME> (120RH) connector A/18, FAP (120RH) connector A/20 and GND, FAP (120RH) connector A/21 and GND, FAP (120RH) connector A/22 and GND (Ref. ASM 23-73/23).
**ON A/C 151-199,
B. If the CIDS1/FAP test gives the maintenance message NO FAP DATA:
- make sure that at least one cabin door is open,
- open these CBs:
49VU: 150RH (G01) COM DIR ESS/1
49VU: 157RH (G02) COM DIR ESS/2
121VU:151RH (M06) CIDS/DIR NORM/1
121VU:156RH (M07) CIDS/DIR NORM/2,
- wait for approx. 10 s and close the CBs 156RH and 157RH.
- wait for approx. 120 s,
- do the CIDS2/FAP test.
(1) If the CIDS2/FAP test does not give the message NO FAP DATA:
- install a new DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-400-001).
(a) If the fault continues:
- replace the ATTENDANT PANEL-FORWARD (120RH) (Ref. AMM TASK 23-73-12-000-002) and (Ref. AMM TASK 23-73-12-400-002)
1 If the fault continues:
_
- do a check and repair the wiring between: DIR-CIDS (101RH) connector AA/A12 and FAP (120RH) connector A/1, DIR-CIDS (101RH) connector AA/B12 and FAP (120RH) connector A/2, DIR-CIDS (101RH) connector AA/D12 and FAP (120RH) connector A/4, DIR-CIDS (101RH) connector AA/E12 and FAP (120RH) connector A/5, CB 170RH and FAP (120RH) connector A/18, FAP (120RH) connector A/3 and GND, FAP (120RH) connector A/6 and GND,
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 106-149, 151-199, 301-399, 401-499, ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page A293
Aug 01/05 CES
FAP (120RH) connector A/17 and GND (Ref. ASM 23-73/09).
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
C. Install the removed DIR-CIDS (101RH) (Ref. AMM TASK 23-73-34-400-001). **ON A/C ALL
D. Do the test given in Para. 3.A.
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
TASK 23-73-00-810-856
PTP - Fault in the Programming and Test Panel
1. Possible Causes
_______________
- PROGRAMMING AND TEST PANEL (110RH)
- DIR-CIDS, 1 (101RH)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 23-73-12-000-001 Removal of the Forward Attendant Panel (FAP) frame 121RH AMM 23-73-12-400-001 Installation of the Forward Attendant Panel (FAP)
frame 121RH
AMM 23-73-34-000-001 Removal of the CIDS Director (101RH,102RH)
AMM 23-73-34-400-001 Installation of the CIDS Director (101RH,102RH)
ASM 23-73/09
3. Fault Confirmation
__________________
A. Test
(1) Do the PTP test through the CFDS.
4. Fault Isolation
_______________
A. If the CFDS gives the maintenance message P&T PNL:
- replace the PROGRAMMING AND TEST PANEL (110RH) (Ref. AMM TASK 23-73-12-000-001) and (Ref. AMM TASK 23-73-12-400-001).
**ON A/C 001-049, 051-099, 101-105, 201-299,
B. If the fault continues:
- gemove the DIR-CIDS (101RH) (Ref. AMM TASK 23-73-34-000-001),
- make sure that at least one cabin door is open,
- close these CBs:
49VU: 150RH (G02) CIDS/DIR 1 & 2/ESS
121VU:151RH (M05) CIDS/DIR 1 & 2/NORM,
- stop for approx. 120 s,
- do the PTP test again.