• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-28 09:27来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 Aug 01/05 CES (1) If the fault continues:


 - do a check for 28 VDC with a MULTIMETER - STANDARD at pins B and C on the related PCB 2038VU (Ref. ASM 23-73/13) and (Ref. ASM 23-73/14).
 (a) If there is approx. 28 VDC:

 - replace the related PCB 2038VU (Ref. AMM TASK 23-73-49-000-001) and (Ref. AMM TASK 23-73-49-400-001).

 (b) If there is no 28 VDC:


 - do a check for 28VDC with a MULTIMETER - STANDARD at the related DEU-A between the related pairs of connectors given below: Connectors C/7 and C/18 or Connectors C/9 and C/19 or Connectors C/11 and C/20 (Ref. ASM 23-73/13) and (Ref. ASM 23-73/14).
 1 If there is approx. 28 VDC:
_
 - do a check and repair the wiring if necessary between the: Pins B and C on the related PCB and the related DEU-A pairs of connectors given below: Connectors C/7 and C/18 or Connectors C/9 and C/19 or Connectors C/11 and C/20 (Ref. ASM 23-73/13) and (Ref. ASM 23-73/14).
 2 If there is no 28 VDC:
_
 - replace the related DEU-A (200RHxx) (Ref. AMM TASK 23-73-46-000-001) and (Ref. AMM TASK 23-73-46-400-001).
 C. For Pax Call Lamps / Seatrow Identifier with LED (without bulbs)
 If the related Pax Call Lamp / Seatrow Identifier does not come on:
 - do a check for 28 VDC with a MULTIMETER - STANDARD at pins B and C on the related PCB 509RH/510RH (Ref. ASM 23-73/13) and (Ref. ASM 23-73/14).
 (1) If there is approx. 28 VDC:

 - replace the related PCB 509RH/510RH (Ref. AMM TASK 23-73-49-000-001) and (Ref. AMM TASK 23-73-49-400-001).

 (2) If there is no 28 VDC:


 - do a check for 28VDC with a MULTIMETER - STANDARD at the related DEU-A between the related pairs of connectors given below: Connectors C/7 and C/18 or Connectors C/9 and C/19 or Connectors C/11 and C/20 (Ref. ASM 23-73/13) and (Ref. ASM 23-73/14).
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 151-199, ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page B288
 201-299, Aug 01/05 CES


 (a) If there is approx. 28 VDC:

 - do a check and repair the wiring if necessary between the: Pins B and C on the related PCB and the related DEU-A pairs of connectors given below: Connectors C/7 and C/18 or Connectors C/9 and C/19 or Connectors C/11 and C/20 (Ref. ASM 23-73/13) and (Ref. ASM 23-73/14).

 (b) If the fault continues:


 - replace the related DEU-A (200RHxx) (Ref. AMM TASK 23-73-46-000-001) and (Ref. AMM TASK 23-73-46-400-001).
R **ON A/C 106-149, 301-399, 401-499,
 C. If the test confirms the fault: replace the related PCB 601RH (Ref. AMM TASK 23-73-49-000-001) and (Ref. AMM TASK 23-73-49-400-001).
 **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
 D. If the CIDS1/SIGN LAMP test gives the maintenance message PAX CALL LAMP XX and the lamps come on, no other maintenance action is necessary.
 NOTE : An erroneous class 3 fault message will be recorded for each LED
____ PAX CALL / Seatrow Identifier (without bulbs), if the test of the related lamps is not deactivated in the CAM.
 **ON A/C ALL
 5. Close-up
________
 A. Do the test as given in Para. 3.A.


R **ON A/C 106-149, 301-399, 401-499,
 TASK 23-73-00-810-933
 CAM transmission failure
 1. Possible Causes
_______________
 - FAP (120RH)

 - MODULE-CABIN ASSIGNMENT (115RH)


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
AMM 23-73-00-740-010 Interface and Power-Up Test of the Cabin
 Intercommunication Data System (CIDS) via the CFDS AMM 23-73-12-000-007 Removal of the Flight Attendant Panel (FAP) 120RH AMM 23-73-12-400-007 Installation of the Flight Attendant Panel (FAP)
 120RH AMM 23-73-19-000-002 Removal of the Cabin Assignment Module (115RH) AMM 23-73-19-400-002 Installation of the Cabin Assignment Module (115RH)
 3. Fault Confirmation
__________________
 A. Test
 (1) Do the CIDS Interface and Power-Up Test via the CFDS (Ref. AMM TASK 23-73-00-740-010).
 4. Fault Isolation
_______________
 A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
 B. If the test confirms the fault:
 - replace the FAP (120RH) (Ref. AMM TASK 23-73-12-000-007) and (Ref. AMM TASK 23-73-12-400-007).
 (1) If the fault continues:
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 COMMUNICATIONS 通讯2(144)