**ON A/C ALL
C. Install the removed DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-400-001).
D. Do the test given in Para. 3.A.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page 275
Aug 01/05R
CES
TASK 23-73-00-810-801
DEU-A - Fault in DEU-A 200RHxx with connected Systems/Devices
1. Possible Causes
_______________
- DIR-CIDS, 1 (101RH)
- DEU-A (200RHxx)
- DEU mount 2010VUxx
- wiring
- Connection Box 208RHxx
- Termination Box 209RHxx
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 23-73-00-740-005 BITE Test of the Cabin Intercommunication Data System
(CIDS) through the CFDS AMM 23-73-34-000-001 Removal of the CIDS Director (101RH,102RH) AMM 23-73-34-400-001 Installation of the CIDS Director (101RH,102RH) AMM 23-73-42-000-001 Removal of the Connection Box AMM 23-73-42-400-001 Installation of the Connection Box AMM 23-73-43-000-001 Removal of the Termination Box AMM 23-73-43-400-001 Installation of the Termination Box AMM 23-73-46-000-001 Removal of the Decoder/Encoder Unit (DEU) A 200RH AMM 23-73-46-400-001 Installation of the Decoder/Encoder Unit (DEU) A
200RH
AMM 23-73-48-000-001 Removal of the DEU A / DEU B - Mount
AMM 23-73-48-400-001 Installation of the DEU A / DEU B - Mount
ASM 23-73/06
ASM 23-73/07
ASM 23-73/08
3. Fault Confirmation
__________________
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
A. Test
(1) Do the CIDS/DEU-A test through the CFDS (via CIDS1).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page 276
Aug 01/05R CES
R **ON A/C 106-149, 301-399, 401-499,
A. Test
(1) Do the CIDS Interface and Power-Up Test via the CFDS (Ref. AMM TASK 23-73-00-740-005).
**ON A/C ALL
4. Fault Isolation
_______________
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
**ON A/C 001-049, 051-099, 101-105, 201-299,
B. If the CIDS1/DEU-A test gives the maintenance message DEU-A 200RHxx:
- remove the DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-000-001),
- make sure that at least one cabin door is open,
- close these CBs:
49VU: 150RH (G02) CIDS/DIR 1 & 2/ESS
121VU:151RH (M05) CIDS/DIR 1 & 2/NORM,
- stop for approx. 120 s,
- do the CIDS/DEU-A test (via CIDS2).
(1) If the CIDS2/DEU-A test is OK:
- install a new DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-400-001)
(2) If the fault continues:
- make sure that the related coding switch(es) is (are) set to the correct DEU-A address (Ref. ASM 23-73/06), (Ref. ASM 23-73/07) and (Ref. ASM 23-73/08).
(a) If the coding switch position(s) is (are) not correct:
- make an adjustment of the related coding switch(es).
(b) If the coding switch position(s) is (are) correct:
- replace the DEU-A (200RHxx) (Ref. AMM TASK 23-73-46-000-001) and (Ref. AMM TASK 23-73-46-400-001).
1 If the fault continues:
_
- replace the DEU mount 2010VUxx (Ref. AMM TASK 23-73-48-000-001) and (Ref. AMM TASK 23-73-48-400-001).
a If the fault continues:
_
- do a check for 28VDC at DEU mount 2010VUxx connector A/8, 28VDC at DEU mount 2010VUxx connector A/5, GND at DEU mount 2010VUxx connector A/7,
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : ALL ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page 277
Aug 01/05 CES (Ref. ASM 23-73/06) and (Ref. ASM 23-73/07) and repair the wiring if necessary.
R **ON A/C 106-149, 301-399, 401-499,
B. If the fault continues:
- make sure that the related coding switch(es) is (are) set to the correct DEU-A address (Ref. ASM 23-73/06), (Ref. ASM 23-73/07) and (Ref. ASM 23-73/08).
(1) If the coding switch position(s) is (are) not correct:
- make an adjustment of the related coding switch(es). 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 COMMUNICATIONS 通讯2(63)