TASK 23-73-00-810-934
FAP - OBRM failure
1. Possible Causes
_______________
- FAP (120RH)
- CIDS OBRM (116RH)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 23-73-00-740-010 Interface and Power-Up Test of the Cabin
Intercommunication Data System (CIDS) via the CFDS AMM 23-73-12-000-007 Removal of the Flight Attendant Panel (FAP) 120RH AMM 23-73-12-400-007 Installation of the Flight Attendant Panel (FAP)
120RH AMM 23-73-21-000-001 Removal of the On Board Replaceable Module (OBRM) 116RH AMM 23-73-21-400-001 Installation of the On Board Replaceable Module (OBRM) 116RH
3. Fault Confirmation
__________________
A. Test
(1) Do the CIDS Interface and Power-Up Test via the CFDS (Ref. AMM TASK 23-73-00-740-010).
4. Fault Isolation
_______________
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
B. If the test confirms the fault:
- replace the FAP (120RH) (Ref. AMM TASK 23-73-12-000-007) and (Ref. AMM TASK 23-73-12-400-007).
(1) If the fault continues:
- replace the CIDS OBRM (116RH) (Ref. AMM TASK 23-73-21-000-001) and (Ref. AMM TASK 23-73-21-400-001).
5. Close-up
________
A. Do the test as given in Para. 3.A.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 106-149, 301-399, 401-499, ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page B291
Aug 01/05 CES
TASK 23-73-00-810-935
CAM - Director software mismatch
1. Possible Causes
_______________
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 23-73-00-740-010 Interface and Power-Up Test of the Cabin Intercommunication Data System (CIDS) via the CFDS
3. Fault Confirmation
__________________
A. Test
(1) Do the CIDS Interface and Power-Up Test via the CFDS (Ref. AMM TASK 23-73-00-740-010).
4. Fault Isolation
_______________
A. If the test gives a different maintenance message, do the trouble
shooting procedure related to the maintenance message.
B. If the test confirms the fault:
- make sure that a correct OBRM (116 RH) and/or CAM (115RH) is installed. NOTE : The OBRM standart must be in accordance with the standart from the
____
CAM.
5. Close-up
________
A. Do the test as given in Para. 3.A.
TASK 23-73-00-810-936
CAM/DIR 2 software mismatch
1. Possible Causes
_______________
- MODULE-CABIN ASSIGNMENT (115RH)
- CIDS OBRM (116RH)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 23-73-00-740-010 Interface and Power-Up Test of the Cabin Intercommunication Data System (CIDS) via the CFDS
3. Fault Confirmation
__________________
A. Test
(1) Do the CIDS Interface and Power-Up Test via the CFDS (Ref. AMM TASK 23-73-00-740-010).
4. Fault Isolation
_______________
A. If the test gives a different maintenance message, do the trouble
shooting procedure related to the maintenance message.
B. If the test confirms the fault:
- make sure that the MODULE-CABIN ASSIGNMENT (115RH) standart is in accordance with the CIDS OBRM (116RH) standart.
5. Close-up
________
A. Do the test given in para. 3.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 COMMUNICATIONS 通讯2(145)