(1) If the test is OK:
- install a new DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-400-001).
**ON A/C 151-199,
B. If the fault continues:
- make sure that at least one cabin door is open,
- open these CBs:
49VU: 150RH (G01) COM DIR ESS/1
49VU: 157RH (G02) COM DIR ESS/2
121VU:151RH (M06) CIDS/DIR NORM/1
121VU:156RH (M07) CIDS/DIR NORM/2,
- wait for approx. 10 s and close the CBs 156RH and 157RH.
- stop for approx. 120 s,
- do the PTP test again.
(1) If the test is OK:
- install a new DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-400-001).
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
C. If the fault continues:
- do a check and repair the wiring between: CB 161RH and the PTP (115RH) connector A/17, DIR-CIDS (101RH) connector AA/F12 and PTP (115RH) connector A/1, DIR-CIDS (101RH) connector AA/G12 and PTP (115RH) connector A/2, DIR-CIDS (101RH) connector AA/J12 and PTP (115RH) connector A/4, DIR-CIDS (101RH) connector AA/K12 and PTP (115RH) connector A/5, DIR-CIDS (102RH) connector AA/F12 and PTP (115RH) connector A/1, DIR-CIDS (102RH) connector AA/G12 and PTP (115RH) connector A/2, DIR-CIDS (102RH) connector AA/J12 and PTP (115RH) connector A/4, DIR-CIDS (102RH) connector AA/K12 and PTP (115RH) connector A/5, PTP (115RH) connector A/3 and GND, PTP (115RH) connector A/8 and GND, PTP (115RH) connector A/16 and GND (Ref. ASM 23-73/09).
D. Install the removed DIR-CIDS (101RH) (Ref. AMM TASK 23-73-34-400-001).
E. Do the test given in Para. 3.A.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 151-199, ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page A296
201-299, Aug 01/05 CES
**ON A/C ALL
TASK 23-73-00-810-878
AAP - Fault in the AAP (126RH)
1. Possible Causes
_______________
- DIR-CIDS, 1 (101RH)
- ATTENDANT PANEL-AFT (126RH)
- DEU-B (300RH5)
- AAP (126RH)
- DECODER/ENCODER UNIT B (300RH7)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 23-73-00-740-005 BITE Test of the Cabin Intercommunication Data System (CIDS) through the CFDS AMM 23-73-00-740-010 Interface and Power-Up Test of the Cabin
Intercommunication Data System (CIDS) via the CFDS AMM 23-73-13-000-001 Removal of the AFT Attendant Panel 126RH AMM 23-73-13-400-001 Installation of the AFT Attendant Panel 126RH AMM 23-73-34-000-001 Removal of the CIDS Director (101RH,102RH) AMM 23-73-34-400-001 Installation of the CIDS Director (101RH,102RH) AMM 23-73-47-000-001 Removal of the Decoder/Encoder Units (DEU) B 300RH AMM 23-73-47-400-001 Installation of the Decoder/Encoder Unit (DEU) B
300RH ASM 23-73/10
3. Fault Confirmation
__________________
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
A. Test
(1) Do the CIDS1 BITE test through the CFDS (Ref. AMM TASK 23-73-00-740-005).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page A297
Aug 01/05R
CES R **ON A/C 106-149, 301-399, 401-499,
A. Test
(1) Do the CIDS Interface and Power-Up Test via the CFDS (Ref. AMM TASK 23-73-00-740-010).
**ON A/C ALL
4. Fault Isolation
_______________
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
**ON A/C 001-049, 051-099, 101-105, 201-299,
B. If the CIDS1 BITE test gives the maintenance message ATTND PNL AFT:
- remove the DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-000-001).
- make sure that at least one cabin door is open,
- close these CBs:
49VU: 150RH (G02) CIDS/DIR 1 & 2/ESS
121VU:151RH (M05) CIDS/DIR 1 & 2/NORM,
- stop for approx. 120 s,
- do the CIDS2 BITE test.
(1) If the CIDS2 BITE test does not give the message ATTND PNL AFT:
- install a new DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-400-001).
(a) If the fault continues:
- replace the ATTENDANT PANEL-AFT (126RH) (Ref. AMM TASK 23-73-13-000-001) and (Ref. AMM TASK 23-73-13-400-001).