 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 301-399, ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page A202
 Aug 01/05 CES b If there is continuity:


_
 - reconnect the connector to the DEU CONNECTION BOX (208RH1).

 - do the steps 4. B. (6) again for the subsequent DEU CONNECTION BOXES until the maintenance message stops: DIR-CIDS, 1 (101RH) and DEU CONNECTION BOX (208RH3) connector, DIR-CIDS, 1 (101RH) and DEU CONNECTION BOX (208RH5) connector, DIR-CIDS, 1 (101RH) and DEU CONNECTION BOX (208RH7) connector, DIR-CIDS, 1 (101RH) and DEU CONNECTION BOX (208RH9) connector, DIR-CIDS, 1 (101RH) and DEU CONNECTION BOX (208RH11) connector, DIR-CIDS, 1 (101RH) and DEU CONNECTION BOX (208RH13) connector, DIR-CIDS, 1 (101RH) and DEU TERMINATION BOX (209RH1) connector,


 (7) If the resistance (line to line) is less than 80 ohms (short circuit):
 - remove the DEU-A (200RH15) (Ref. AMM TASK 23-73-46-000-001).

 - do a check for a short circuit again.


 (a) If there is no short circuit:

 - install a new DEU-A (200RH15) (Ref. AMM TASK 23-73-46-400-001).

 (b) If there is a short circuit:

 - install the removed DEU-A (200RH15) (Ref. AMM TASK 23-73-46-400-001).

 - disconnect the electrical connector from the DEU TERMINATION BOX (209RH1) (Ref. ASM 23-73/06),

 - do a check for a short circuit again.

 


 1 If there is a short circuit:
_
 - reconnect the electrical connector to the DEU TERMINATION BOX (209RH1),

 - do the steps 4. B. (7) again for the subsequent DEUs and DEU CONNECTION BOXES until the maintenance message stops: (Ref. ASM 23-73/06) DEU-A (200RH13) and DEU CONNECTION BOX (208RH13), DEU-A (200RH11) and DEU CONNECTION BOX (208RH11), DEU-A (200RH9) and DEU CONNECTION BOX (208RH9), DEU-A (200RH7) and DEU CONNECTION BOX (208RH7), DEU-A (200RH5) and DEU CONNECTION BOX (208RH5), DEU-A (200RH3) and DEU CONNECTION BOX (208RH3), DEU-A (200RH1) and DEU CONNECTION BOX (208RH1),


 2 If there is no short circuit:
_
 - do a check for a short circuit at the disconnected connector between the pins A/9 and A/10 (Ref. ASM 23-73/06)
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : 301-399, ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page A203
 Aug 01/05R CES


 a If there is a short circuit:
_
 - repair the wiring between the related CONNECTION BOX (208RHxx) and the DEU TERMINATION BOX (209RH1) CONNECTION BOX (208RHxx) (Ref. ASM 23-73/06).
 b If there is no short circuit:
_
 - replace the DEU TERMINATION BOX (209RH1) (Ref. AMM TASK 23-73-43-000-001) and (Ref. AMM TASK 23-73-43-400-001).
R **ON A/C 401-499,

R B. If the Interface and Power-Up Test gives the maintenance message CIDS TOP
R BUS 1L/DIR1 (101RH):
R - remove the DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-000-001),
R - make sure that at least one cabin door is open,
R - close these CBs:
R 49VU: 157RH COM/CIDS/DIR/2
R 49VU: 18WH AIR COND/CIDS/SDF/DIR 2 ESS,
R 120VU:156RH COM NAV/CIDS/DIR/NORM/2
R 122VU: 14WH AIR COND/CIDS/SDF/DIR NORM/2
R - wait for approx. 120 s,
R - do the CIDS2 Interface and Power-Up Test via the MCDU/CFDS.

R (1) If the CIDS2 Interface and Power-Up Test is OK:
R - install a new DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-400-001).

R (2) If the fault continues:
R - remove the DIR-CIDS, 2 (102RH) (Ref. AMM TASK 23-73-34-000-001).
R - during the installation of the DIR-CIDS, 1 (101RH) do not close
R these CBs:
R 49VU: 157RH COM/CIDS/DIR/2
R 49VU: 18WH AIR COND/CIDS/SDF/DIR 2 ESS,
R 120VU:156RH COM NAV/CIDS/DIR/NORM/2
R 122VU: 14WH AIR COND/CIDS/SDF/DIR NORM/2
R - install the DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-400-001).
R - do the Interface and Power-Up Test via the MCDU/CFDS.

R (3) If the Interface And Power-Up Test is OK:
R - install a new DIR-CIDS, 2 (102RH) (Ref. AMM TASK 23-73-34-400-001).

R (4) If the fault continues:
R - remove the DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-000-001)
R - open these CBs:
R 49VU: 154RH COM NAV/CIDS/DEU A ESS/LINE 1
R 49VU: 155RH COM NAV/CIDS/DEU A ESS/LINE 2
R 120VU: 163RH COM NAV/CIDS/DEU A NORM/L FWD
R 120VU: 167RH COM NAV/CIDS/DEU A NORM/L AFT
R - make sure that the resistance (line to line) at DIR-CIDS, 1 (101RH)
R and DIR-CIDS, 2 (102RH) connector AA/D15 and connector AA/E15 is
R between approx. 80 and 120 ohms (Ref. ASM 23-73/06).