A. Do the test as given in Para. 3.A.
TASK 23-73-00-810-922
CAM - Failure by active Director
1. Possible Causes
_______________
- MODULE-CABIN ASSIGNMENT (115RH)
- DIR-CIDS, 1 (101RH)
- FAP (120RH)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 23-73-00-740-010 Interface and Power-Up Test of the Cabin
Intercommunication Data System (CIDS) via the CFDS AMM 23-73-12-000-007 Removal of the Flight Attendant Panel (FAP) 120RH AMM 23-73-12-400-007 Installation of the Flight Attendant Panel (FAP)
120RH AMM 23-73-19-000-002 Removal of the Cabin Assignment Module (115RH) AMM 23-73-19-400-002 Installation of the Cabin Assignment Module (115RH) AMM 23-73-34-000-001 Removal of the CIDS Director (101RH,102RH) AMM 23-73-34-400-001 Installation of the CIDS Director (101RH,102RH)
3. Fault Confirmation
__________________
A. Test
(1) Do the CIDS Interface and Power-Up Test via the CFDS (Ref. AMM TASK 23-73-00-740-010).
4. Fault Isolation
_______________
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
B. If the test confirms the fault:
- replace the MODULE-CABIN ASSIGNMENT (115RH) (Ref. AMM TASK 23-73-19-000-002) and (Ref. AMM TASK 23-73-19-400-002).
(1) If the fault continues:
- replace the DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-000-001) and (Ref. AMM TASK 23-73-34-400-001).
(a) If the fault continues:
- replace the FAP (120RH) (Ref. AMM TASK 23-73-12-000-007) (Ref. AMM TASK 23-73-12-400-007).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 106-149, 301-399, 401-499, ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page B270
Aug 01/05 CES
5. Close-up
________
A. Do the test as given in Para. 3.A.
TASK 23-73-00-810-923
CAM - Failure by passive Director
1. Possible Causes
_______________
- DIR-CIDS, 2 (102RH)
- MODULE-CABIN ASSIGNMENT (115RH)
- FAP (120RH)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 23-73-00-740-010 Interface and Power-Up Test of the Cabin
Intercommunication Data System (CIDS) via the CFDS AMM 23-73-12-000-007 Removal of the Flight Attendant Panel (FAP) 120RH AMM 23-73-12-400-007 Installation of the Flight Attendant Panel (FAP)
120RH AMM 23-73-19-000-002 Removal of the Cabin Assignment Module (115RH) AMM 23-73-19-400-002 Installation of the Cabin Assignment Module (115RH) AMM 23-73-34-000-001 Removal of the CIDS Director (101RH,102RH) AMM 23-73-34-400-001 Installation of the CIDS Director (101RH,102RH)
3. Fault Confirmation
__________________
A. Test
(1) Do the CIDS Interface and Power-Up Test via the CFDS (Ref. AMM TASK 23-73-00-740-010).
4. Fault Isolation
_______________
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
B. If the test confirms the fault:
- replace the DIR-CIDS, 2 (102RH) (Ref. AMM TASK 23-73-34-000-001) and (Ref. AMM TASK 23-73-34-400-001).
(1) If the fault continues:
- replace the MODULE-CABIN ASSIGNMENT (115RH) (Ref. AMM TASK 23-73-19-000-002) and (Ref. AMM TASK 23-73-19-400-002).
(a) If the fault continues:
- replace the FAP (120RH) (Ref. AMM TASK 23-73-12-000-007) (Ref. AMM TASK 23-73-12-400-007).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 106-149, 301-399, 401-499, ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page B272
Aug 01/05 CES
5. Close-up
________
A. Do the test as given in Para. 3.A.
TASK 23-73-00-810-924
FAP - active Director no data from FAP (x)
1. Possible Causes
_______________
- DIR-CIDS, 1 (101RH)
- FAP (120RH) 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 COMMUNICATIONS 通讯2(139)