- do a check for a short circuit again.
1 If there is no short circuit:
_
- install a new DEU-B (300RH8) (Ref. AMM TASK 23-73-47-400-001).
2 If the fault continues:
_
- disconnect the electrical connector from the DEU TERMINATION BOX (309RH2).
- do a check for a short circuit again.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 106-149, 401-499, ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page A276
Aug 01/05 CES a If there is no short circuit:
_
- install a new DEU TERMINATION BOX (309RH2) (Ref. AMM TASK 23-73-43-000-001) and (Ref. AMM TASK 23-73-43-400-001).
b If the fault continues:
_
- install the removed DEU-B (300RH8) (Ref. AMM TASK 23-73-47-400-001),
- reconnect the electrical connector to the DEU TERMINATION BOX (309RH2) (Ref. ASM 23-73/06),
- remove the DEU-B (300RH6) (Ref. AMM TASK 23-73-47-000-001),
- do a check for a short circuit again.
- b.1. If there is no short circuit:
- install a new DEU-B (300RH6) (Ref. AMM TASK 23-73-47-400-001),
- b.2. If the fault continues:
- disconnect the electrical connector from the DEU CONNECTION BOX (308RH6),
- do a check for a short circuit again.
- b.2.1. If there is no short circuit:
- do a check for a short circuit at the disconnected connector between pin 9 and GND (pin 4) and between pin 10 and GND (pin 4).
- b.2.1.1. If there is a short circuit:
- repair the wiring between the DEU CONNECTION BOX (308RH6) and the DEU TERMINATION BOX (309RH2) (Ref. ASM 23-73/06).
- b.2.1.2. If there is no short circuit:
- install a new DEU CONNECTION BOX (308RH2) (Ref. AMM TASK 23-73-42-400-001)
- b.2.2. If there is a short circuit:
- install the removed DEU-B (300RH6) (Ref. AMM TASK 23-73-47-400-001),
- reconnect the electrical connector to the DEU CONNECTION BOX (308RH6),
- do the steps (4. B. (5) (b) 2 b) again for the subsequent DEU(s) and DEU CONNECTION BOX(es) until the maintenance message stops: (Ref. ASM 23-73/06) DEU CONNECTION BOX (308RH2).
(6) If the resistance (line to line) is more than 140 ohms (open circuit):
- disconnect the electrical connector from the DEU TERMINATION BOX (309RH2),
- make sure that the resistance (line to line) is not more than 140 ohms (open circuit) between: DEU TERMINATION BOX (309RH2) pin A/1 and pin A/2
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 106-149, 401-499, ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page A277
Aug 01/05 CES
(a) If there is an open circuit:
- install a new DEU TERMINATION BOX (309RH2) (Ref. AMM TASK 23-73-43-000-001) and (Ref. AMM TASK 23-73-43-400-001).
(b) If there is no open circuit:
- reconnect the electrical connector to the DEU TERMINATION BOX (309RH2)
- disconnect the electrical connector from the DEU CONNECTION BOX (308RH2).
- do a check of the wiring (continuity-check) between: DIR-CIDS (101RH) connector AA/A14 and the DEU TERMINATION BOX connector pin A/2, DIR-CIDS (101RH) connector AA/B14 and the DEU TERMINATION BOX connector pin A/1.
1 If there is no continuity:
_
- repair the wiring between the DIR-CIDS (101RH) and the connector (Ref. ASM 23-73/06).
2 If there is continuity:
_
- do a check of the wiring (continuity-check) between: DEU CONNECTION BOX (308RH2) pin A/1 and pin A/9 , DEU CONNECTION BOX (308RH2) pin A/2 and pin A/10.
a If there is no continuity:
_
- install a new DEU CONNECTION BOX (308RH2) (Ref. AMM TASK 23-73-42-000-001) and (Ref. AMM TASK 23-73-42-400-001).
b If there is continuity:
_
- reconnect the connector to the DEU CONNECTION BOX (308RH2)
- do the steps 4. B. (6) again for the subsequent DEU CONNECTION/ TERMINATION BOX(es) until the maintenance message stops: DIR-CIDS (101RH) and DEU CONNECTION BOX (308RH6)/connector, DIR-CIDS (101RH) and DEU TERMINATION BOX (309RH2)/connector.
(7) If the resistance (line to line) is less than 80 ohms (short circuit):
- remove the DEU-B (300RH8) (Ref. AMM TASK 23-73-47-000-001),
- do a check for a short circuit again.
(a) If there is no short circuit:
- install a new DEU-B (300RH8) (Ref. AMM TASK 23-73-47-400-001),
(b) If there is a short circuit:
- install the removed DEU-B (300RH8) (Ref. AMM TASK 23-73-47-400-001), 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 COMMUNICATIONS 通讯2(108)