TASK 23-73-00-810-902
No PA and no Interphone from both AFT ATTND Stations
1. Possible Causes
_______________
- DEU-B (300RH5)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 23-73-47-000-001 Removal of the Decoder/Encoder Units (DEU) B 300RH AMM 23-73-47-400-001 Installation of the Decoder/Encoder Unit (DEU) B 300RH AMM 25-62-00-210-001 Check Pressure at Door Escape-Slide/Slide Raft Pressure Gage (if not connected to CIDS)
3. Fault Confirmation
__________________
A. Do this test:
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the Programming and Test Panel On the PTP: (PTP):
- push the SYSTEM TEST line - the SYSTEM TEST menu comes on.
select key.
- push the CONT line select key
until the DEU-B line select key
comes on.
- push the DEU-B line select key. - the DEU-B TEST menu page comes on with a flashing display WAIT FOR RESPONSE.
- after some seconds the following message comes on: ATA 23-73-47 DEU-B 300RH5
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : 001-049, 051-099, 101-105, 151-199, ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page B236
201-299, Aug 01/05R
CES 4. Fault Isolation
_______________
A. If the DEU-B 300RH5 failure message comes on:
- replace the DEU-B (300RH5) (Ref. AMM TASK 23-73-47-000-001) and (Ref. AMM TASK 23-73-47-400-001).
NOTE : If no spare DEU-B is available and to avoid AOG due to two
____ inoperative ATTND stations it is possible to swap DEU-B 300RH5 with DEU-B 300RH4. Ignore the SLIDE PRESS LOW message on the PTP generated by the swapped faulty DEU-B 300RH5. To make sure that the pressure gage of the RH offwing slide inflation-reservoir is in the correct range do the Inspection/Check procedure of the offwing slide inflation-reservoir (Ref. AMM TASK 25-62-00-210-001).
5. Close-up
________
A. Do this test:
NOTE : In case you have swapped the DEU-B 300RH5 with DEU-B 300RH4 ignore
____ the failure message generated by the faulty DEU-B on the position of DEU-B 300RH4.
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the Programming and Test Panel On the PTP: (PTP):
- push the SYSTEM TEST line - the SYSTEM TEST menu comes on.
select key.
- push the CONT line select key
until the DEU-B line select key
comes on.
- push the DEU-B line select key. - the DEU-B TEST menu page comes on with a flashing display WAIT FOR RESPONSE.
- after some seconds the following message comes on: ATA 23-73-47 TEST OK
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : 001-049, 051-099, 101-105, 151-199, ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page B237
201-299, Aug 01/05R
CES TASK 23-73-00-810-903
CFDS - Mandatory Layout or Emergency Mode in use
1. Possible Causes
_______________
- PROGRAMMING AND TEST PANEL (110RH)
- DIR-CIDS, 1 (101RH)
- MODULE-CABIN ASSIGNMENT (115RH)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 23-73-00-740-005 BITE Test of the Cabin Intercommunication Data System
(CIDS) through the CFDS AMM 23-73-18-000-001 Removal of the Programming and Test Panel 110RH AMM 23-73-18-400-001 Installation of the Programming and Test Panel 110RH AMM 23-73-19-000-001 Removal of the Cabin Assignment Module (115RH) AMM 23-73-19-400-001 Installation of the Cabin Assignment Module (115RH) AMM 23-73-34-000-001 Removal of the CIDS Director (101RH,102RH) AMM 23-73-34-400-001 Installation of the CIDS Director (101RH,102RH) ASM 23-73/09
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 COMMUNICATIONS 通讯2(129)