(b) If there is no 28 VDC:
- replace the related DEU-A (200RHxx) (Ref. AMM TASK 23-73-46-000-001) and (Ref. AMM TASK 23-73-46-400-001).
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
C. If the CIDS1/SIGN LAMP test gives the maintenance message PAX CALL LAMP XX and the lamps come on, no other maintenance action is necessary.
NOTE : An erroneous class 3 fault message will be recorded for each LED
____ PAX CALL LAMP (without bulbs), if the test of the related lamps is not deactivated in the CAM.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page B284
Aug 01/05 CES
**ON A/C ALL
5. Close-up
________
A. Do the test as given in Para. 3.A.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page B285
Aug 01/05R
CES
TASK 23-73-00-810-930
PAX CALL LAMP/ Seatrow Identifier Fault
1. Possible Causes
_______________
- INDICATOR LIGHT-PASSENGER CALL/SEAT ROW IDENTIFIER (505RH)
- INDICATOR LIGHT-PASSENGER CALL/SEAT ROW IDENTIFIER (506RH)
- PCB 2038VU
- wiring
- DEU-A (200RHxx)
- PCB 509RH/510RH
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific 2 MULTIMETER - STANDARD
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 23-73-00-710-033 Pax Call Lamps Test from the MCDU AMM 23-73-00-710-035 Operational Test of the Cabin LED Lamps via MCDU AMM 23-73-00-740-010 Interface and Power-Up Test of the Cabin
Intercommunication Data System (CIDS) via the CFDS AMM 23-73-14-000-006 Removal of the Seatrow Call/Numbering Light AMM 23-73-14-400-006 Installation of the Seatrow Call/Numbering Light AMM 23-73-46-000-001 Removal of the Decoder/Encoder Unit (DEU) A 200RH AMM 23-73-46-400-001 Installation of the Decoder/Encoder Unit (DEU) A
200RH AMM 23-73-49-000-001 Removal of the Printed Circuit Board (PCB) with the Bulbs or LEDs AMM 23-73-49-400-001 Installation of the Printed Circuit Board (PCB) with
the Bulbs or LEDs
ASM 23-73/13
ASM 23-73/14
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page B286
Aug 01/05R CES
3. Fault Confirmation
__________________
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
A. Test for the Pax Call Lamps / Seatrow Identifier.
(1) Do the CIDS1/SIGN LAMP test through the CFDS (Ref. AMM TASK 23-73-00-710-033).
NOTE : An erroneous class 3 fault message will be recorded for each
____ LED PAX CALL LAMP / Seatrow Identifier (without bulbs), if the test of the related lamps is not deactivated in the CAM.
(2) Open at least one PAX-door to make sure that all Pax Call Lamps / Seatrow Identifiers come on.
R **ON A/C 106-149, 301-399, 401-499,
A. Test
(1) Do the CIDS Interface and Power-Up Test via the CFDS (Ref. AMM TASK 23-73-00-740-010).
(2) Do the Operational Test of the Cabin LED Lamps via the CFDS (Ref. AMM TASK 23-73-00-710-035).
**ON A/C ALL
4. Fault Isolation
_______________
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
B. For Pax Call Lamps / Seatrow Identifier with bulbs: If the CIDS1/SIGN LAMP test gives the maintenance message PAX CALL LAMP XX and the lamp does not come on:
NOTE : XX identifies the location of the faulty unit:
____ - SR: ..L/R
- replace the related INDICATOR LIGHT-PASSENGER CALL/SEAT ROW IDENTIFIER (505RH) and/or INDICATOR LIGHT-PASSENGER CALL/SEAT ROW IDENTIFIER (506RH) (Ref. AMM TASK 23-73-14-000-006) and (Ref. AMM TASK 23-73-14-400-006).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : ALL ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page B287