3. Fault Confirmation
__________________
A. Do the CIDS BITE test through the CFDS (Ref. AMM TASK 23-73-00-740-005).
4. Fault Isolation
_______________ R R A. If the test gives a different maintenance message, do the trouble
R shooting procedure related to the maintenance message. R **ON A/C 001-049, 051-099, 101-105, 201-299,
B. If the CFDS gives the maintenance message:
50% DEU-A
DEU-A 200RHXX (all effected DEU-A 200RH are shown)
- remove the DIR-CIDS1 (Ref. AMM TASK 23-73-34-000-001),
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 151-199, ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page 207
201-299, May 01/05 CES
- make sure that at least one cabin door is open.
- close these CBs:
49VU: 150RH (G02) CIDS/DIR 1 & 2/ESS
121VU: 151RH (M05) CIDS/DIR 1 & 2/NORM,
- stop for approx. 120 s,
- do the test again.
(1) If the test is OK:
- install a new DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-400-001).
(2) If the fault continues:
- replace all related DEU-A 200RH (Ref. AMM TASK 23-73-46-000-001) and (Ref. AMM TASK 23-73-46-400-001).
(a) If the fault continues:
- do a check and repair the wiring between the related: DEU mount connector A/8 and CB 163RH, DEU mount connector A/8 and CB 164RH, DEU mount connector A/8 and CB 165RH, DEU mount connector A/8 and CB 166RH, DEU mount connector A/8 and CB 167RH, DEU mount connector A/8 and CB 168RH, DEU mount connector A/5 and CB 154RH, DEU mount connector A/5 and CB 155RH, DEU mount connector A/7 and GND (Ref. ASM 23-73/06) and (Ref. ASM 23-73/07).
**ON A/C 151-199,
B. If the CFDS gives the maintenance message:
50% DEU-A
DEU-A 200RHXX (all effected DEU-A 200RH are shown)
- make sure that at least one cabin door is open.
- open these CBs:
49VU: 150RH (G01) COM DIR ESS/1
49VU: 157RH (G02) COM DIR ESS/2
121VU:151RH (M06) CIDS/DIR NORM/1
121VU:156RH (M07) CIDS/DIR NORM/2,
- wait for approx. 10 s and close 156RH and 157RH,
- stop for approx. 120 s,
- do the CIDS BITE test again.
(1) If the test is OK:
- install a new DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-400-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 151-199, ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page 208
201-299, May 01/05 CES (2) If the fault continues:
- replace all related DEU-A 200RH (Ref. AMM TASK 23-73-46-000-001) and (Ref. AMM TASK 23-73-46-400-001).
(a) If the fault continues:
- do a check and repair the wiring between the related: DEU mount connector A/8 and CB 163RH, DEU mount connector A/8 and CB 164RH, DEU mount connector A/8 and CB 165RH, DEU mount connector A/8 and CB 166RH, DEU mount connector A/8 and CB 167RH, DEU mount connector A/8 and CB 168RH, DEU mount connector A/5 and CB 154RH, DEU mount connector A/5 and CB 155RH, DEU mount connector A/7 and GND (Ref. ASM 23-73/06), (Ref. ASM 23-73/07) and (Ref. ASM 23-73/08).
R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
C. Do the test as given in Para. 3.A.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 151-199, ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page 209
201-299, May 01/05 CES
TASK 23-73-00-810-882
CIDS - No CIDS Function in 20% of a Cabin Zone
1. Possible Causes
_______________
- DIR-CIDS, 1 (101RH)
- DEU-A 200RH
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 COMMUNICATIONS 通讯2(39)