R **ON A/C 106-149, 301-399, 401-499,
A. Test
(1) Do the CIDS Interface and Power-Up Test via the CFDS (Ref. AMM TASK 23-73-00-740-010).
(2) Do the Operational Test of the Cabin LED Lamps via the CFDS (Ref. AMM TASK 23-73-00-710-035).
**ON A/C ALL
4. Fault Isolation
_______________
A. If the test gives a different maintenance message, do the trouble
shooting procedure related to the maintenance message.
**ON A/C 001-049, 051-099, 101-105, 201-299,
B. If the CIDS1/DEU-B test gives the maintenance message DEU-B 300RHx:
- remove the DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-000-001),
- make sure that at least one cabin door is open,
- close these CBs:
49VU: 150RH (G02) CIDS/DIR 1 & 2/ESS
121VU:151RH (M05) CIDS/DIR 1 & 2/NORM,
- stop for approx. 120 s,
- do the CIDS/DEU-B test (via CIDS2).
(1) If the CIDS2/DEU-B test is OK:
- install a new DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-400-001).
(2) If the fault continues:
- make sure that the related coding switch(es) is (are) set to the correct DEU-B address (Ref. ASM 23-73/10) and (Ref. ASM 23-73/11).
(a) If the coding switch(es) is (are) not in the correct position:
- make an adjustment of the related coding switch(es).
(b) If the coding switch(es) is (are) in the correct position:
- replace the related DEU-B (300RHx) (Ref. AMM TASK 23-73-47-000-001) and (Ref. AMM TASK 23-73-47-400-001).
1 If the fault continues:
_
- replace the DEU mount 2011VUx (Ref. AMM TASK 23-73-48-000-001) and (Ref. AMM TASK 23-73-48-400-001).
a If the fault continues:
_
- do a check for 28VDC at DEU mount 2011VUx connector A/8
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page 281
Aug 01/05 CES 28VDC at DEU mount 2011VUx connector A/5 GND at DEU mount 2011VUx connector A/4 (Ref. ASM 23-73/10) and (Ref. ASM 23-73/11) and repair the wiring if necessary.
R **ON A/C 106-149, 301-399, 401-499,
B. If the test confirms the fault:
- make sure that the related coding switch(es) is (are) set to the correct DEU-B address (Ref. ASM 23-73/10) and (Ref. ASM 23-73/11).
(1) If the coding switch(es) is (are) not in the correct position:
- make an adjustment of the related coding switch(es).
(2) If the coding switch(es) is (are) in the correct position:
- replace the related DEU-B (300RHxx) (Ref. AMM TASK 23-73-47-000-001) and (Ref. AMM TASK 23-73-47-400-001).
(a) If the fault continues:
- replace the related Connection Box 308RHxx (Ref. AMM TASK 23-73-42-000-001) and (Ref. AMM TASK 23-73-42-400-001) or Termination Box 309RHxx (Ref. AMM TASK 23-73-43-000-001) and (Ref. AMM TASK 23-73-43-400-001).
1 If the fault continues:
_
- do a check for 28VDC at Connection Box 308RHxx or Termination Box 309RHxx connector A/5 and A/8 and a GND signal at connector A/4 (Ref. ASM 23-73/10) and (Ref. ASM 23-73/11) and repair the wiring if necessary.
**ON A/C 151-199,
B. If the CIDS1/DEU-B test gives the maintenance message DEU-B 300RHx:
- make sure that at least one cabin door is open,
- open these CBs:
49VU: 150RH (G01) COM DIR ESS/1
49VU: 157RH (G02) COM DIR ESS/2
121VU:151RH (M06) CIDS/DIR NORM/1
121VU:156RH (M07) CIDS/DIR NORM/2,
- wait for approx. 10 s and close the CBs 156RH and 157RH,
- stop for approx. 120 s,
- do the CIDS/DEU-B test (via CIDS2).
(1) If the CIDS2/DEU-B test is OK:
- install a new DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-400-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page 282
Aug 01/05 CES (2) If the fault continues:
- make sure that the related coding switch(es) is (are) set to the correct DEU-B address (Ref. ASM 23-73/10) and (Ref. ASM 23-73/11).
(a) If the coding switch(es) is (are) not in the correct position:
- make an adjustment of the related coding switch(es).
(b) If the coding switch(es) is (are) in the correct position:
- replace the related DEU-B (300RHx) (Ref. AMM TASK 23-73-47-000-001) and (Ref. AMM TASK 23-73-47-400-001).
1_ If the fault continues: