- make sure that the NO SMOKING (190RH) switch is in the ON position,
- open these CBs:
49VU: 150RH (G01) COM DIR ESS/1
49VU: 157RH (G02) COM DIR ESS/2
121VU:151RH (M06) CIDS/DIR NORM/1
121VU:156RH (M07) CIDS/DIR NORM/2,
- wait for 10 s and close the CBs 156RH and 157RH,
- stop for approx. 120 s,
- check if the NO SMOKING signs in the cabin come on.
(1) If the test is OK:
- install a new DIR-CIDS (101RH) (Ref. AMM TASK 23-73-34-000-001).
(2) If the fault continues:
- do a check and repair the wiring if necessary between the: DIR-CIDS 101RH connector AB/D15 and NO SMOKING (190RH) switch, DIR-CIDS 101RH connector AB/C13 and SDAC1 (1WV1) connector AA/7H (Ref. ASM 23-73/02).
(a) If the fault continues:
- replace the NO SMOKING (190RH) switch.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 151-199, ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page 254
Aug 01/05 CES
E. If there is no reaction of the AIPs, ACPs and the ATTND-loudspeakers in the cabin:
- make sure that at least one cabin door is open,
- open these CBs:
49VU: 150RH (G01) COM DIR ESS/1
49VU: 157RH (G02) COM DIR ESS/2
121VU:151RH (M06) CIDS/DIR NORM/1
121VU:156RH (M07) CIDS/DIR NORM/2,
- wait for approx. 10 s and close the CBs 156RH and 157RH,
- stop for approx. 120 s,
- push all CALL pushbuttons on the cockpit overhead panel 21VU (CALLS) again,
- check that each CALL pushbutton has an associated reaction in the cabin on the AIP, ACP and ATTND loudspeaker.
(1) If the test is OK:
- install a new DIR-CIDS (101RH) (Ref. AMM TASK 23-73-34-000-001).
(2) If the fault continues:
- do a check and repair the wiring if necessary between the: DIR-CIDS 101RH connector AB/3B and CALLS/FWD (181RH1) switch, DIR-CIDS 101RH connector AB/3C and CALLS/AFT (181RH2) switch, DIR-CIDS 101RH connector AB/3D and CALLS/ALL (181RH3) switch, DIR-CIDS 101RH connector AB/8K and CALLS/EXIT (181RH4) switch, DIR-CIDS 101RH connector AB/3E and CALLS/MID (181RH5) switch, DIR-CIDS 101RH connector AB/A3 and CALLS/EMER CALL (180RH) switch (Ref. ASM 23-73/02).
(a) If the fault continues:
- replace the: CALLS/FWD (181RH1) switch, and/or CALLS/AFT (181RH2) switch and/or CALLS/ALL (181RH3) switch and/or CALLS/EXIT (181RH4) switch and/or CALLS/MID (181RH5) switch and/or CALLS/EMER CALL (180RH) switch.
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
F. Install the removed DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-400-001).
**ON A/C ALL
G. Do the test given in Para. 3.A.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : ALL ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page 255
Aug 01/05 CES
TASK 23-73-00-810-870
ACP - No Indication on one Area Call Panel
1. Possible Causes
_______________
- lamp
- DEU-B 300RH
- ACP 340RHx
- wiring
- ACP 340RHxx
- DEU-B 300RHxx
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 23-73-00-710-035 Operational Test of the Cabin LED Lamps via MCDU AMM 23-73-00-740-005 BITE Test of the Cabin Intercommunication Data System (CIDS) through the CFDS AMM 23-73-00-740-010 Interface and Power-Up Test of the Cabin
Intercommunication Data System (CIDS) via the CFDS AMM 23-73-11-000-001 Removal of the Area Call Panel (ACP) 340RH AMM 23-73-11-400-001 Installation of the Area Call Panel (ACP) 340RH AMM 23-73-47-000-001 Removal of the Decoder/Encoder Units (DEU) B 300RH AMM 23-73-47-400-001 Installation of the Decoder/Encoder Unit (DEU) B
300RH ASM 23-73/10 ASM 23-73/11
3. Fault Confirmation
__________________
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
A. Test
(1) Do the CIDS BITE test through the CFDS (Ref. AMM TASK 23-73-00-740-005).
(2) Do the CIDS1/AREA CALL PANELS test through the CFDS.
中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 COMMUNICATIONS 通讯2(56)